Laserfiche WebLink
- — STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD i <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B moi, �g <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. �l,��MM.� <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE REM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE a 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: a4 rp\A *' Q O 55 7 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.0 B. MANUFACTURED BY: foo V <br /> C. DATE INSTALLED(MOIDAYNEAR) I 1 S 0 D. TANK CAPACITY IN GALLONS: ) p p p <br /> ILTANKCONTENTS IFA-11S MARKED.COMPLETE ITEM C. <br /> A. ❑ 1 MOTOR VEHICLE FUEL © 4 OIL B. C. ❑ la RE <br /> GU E� 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ BO EMPTY ❑ 1 PRODUCT ❑ 1b PREMIUM 4 G113AHOL ❑ 7 METHANOL <br /> ❑ 3 CHEMICALPRODUCT ❑ 95 UNKNOWN2 WASTE 2 LEADEDUNLEADE ❑ 5 JETFUEL <br /> ❑ ❑ 89 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> 0. IF(A.1)1S NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALLTHAT APPLIES IN BOX D AND <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTEDTANK) ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS © 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Pdmwy TARk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 96 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP LK 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A 3 GRAVITY A U W OTHER <br /> B. CONSTRUCTION A& 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A 0 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U /0 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ® 3 INTERSTITIAL — <br /> MONITORING ❑99 OTHER <br /> V.TANK LEAK DETECTION <br /> 1 VISUAL CHECK O 2 INVENTORY RECONCILIATION r-13 VADOZE MONITORING ❑ 4 AUTOMATIC TANK GAUGING ❑ 5 GROUND WATER MONITORING <br /> ❑ 6 TANK TESTING 7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO ❑ <br /> SUBSTANCE REMAINING GA DNS INERTMATERIALI <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJUR , N T ST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> IVRirvTED6 SIGNATUREI „-`�L <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OFT UR NUMBERS BELOW <br /> COUNTY# JURISDICTION# -ACIL ITY# TANK# <br /> STATE I.D.# m �l� <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FORM (12-91) <br /> pa6o�,sej FOR06t1BR6 <br />