My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
139
>
2300 - Underground Storage Tank Program
>
PR0231039
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2021 10:52:34 PM
Creation date
11/2/2018 4:16:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231039
PE
2361
FACILITY_ID
FA0006437
FACILITY_NAME
CHEVRON STATION #90557*** (INACT)
STREET_NUMBER
139
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13730012
CURRENT_STATUS
02
SITE_LOCATION
139 S CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CENTER\139\PR0231039\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
2/29/2012 8:00:00 AM
QuestysRecordID
119913
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
121
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UMD PROGRAM CONSOLIDATED F(,� <br /> TANKS <br /> UNDERGROUND STORAGE TANKS- TANK PAGE 1 <br /> (two pages per tank) <br /> Page 7 of 8 <br /> TYPE O ACTION ❑1 NEW SITE PERMIT [14 AMENDED PERMIT [35 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE <br /> (Cheek one tem only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify oreeon-for bcel one any) (Specify reason-for local use only) X 8 TANK REMOVED 330 <br /> BUSINESS NAME(Some as FACILITY NAME or DBA-Doing Busmee As) 3 FACILITY ID: O Q Q Q Q Q Q Q Q Q Q 1 <br /> Chevron Station#90557 <br /> LOCATION WITHIN SITE(Optionan 431 <br /> 139 S Center SL, Stockton,CA 95202 <br /> L TANK DESCRIPTION (A scaled plot plan with the location ofthe UST system including buildings and landmarks shall be submitted to the low[agency.) <br /> TANKED# 432 TANK MANUFACTURER a33 <br /> COMPARTMENTALIZED TANK ❑Yes No 434 <br /> 38008 JOOR If"Yas",compkre rare page for erL compeanmt. <br /> DATE INSTALLED(YEARIMO) -5 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 1/1/90 1 1000 0 <br /> ADDITIONAL DESCRIPTION(For kcal use only) 438 <br /> IL TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE <br /> 410 <br /> ❑1. MOTOR VEHICLE FUEL ❑la REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (lfine oconplesePehuleon Type) ❑lb. PREMIUM UNLEADED 03. DIESEL ❑6. AVIATION FUEL <br /> ❑2. NON-FUEL PETROLEUM [Ile. MIDGRADE UNLEADED ❑4. GASOHOL ®99.OTHER <br /> [13. CHEMICAL PRODUCT COMMON NAME (fiom Hemrdous M.tetela In enmry page) ml CAS#(fmm mount.maennN In omm,,page) 442 <br /> ®4. HAZARDOUS WASTE <br /> pnch de IBed Di° USED MOTOR OIL N/A <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK 01. SINGLE WALL 3, SINGLE WALL WITH 0 5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one tem only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®I DOUBLE WALL ❑4. SINGLE WALL IN VAULT ❑99. OTHER <br /> TANKMATERIAL-pvnerymnk 0 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 0 5. CONCRETE 0 95. UNKNOWN 444 <br /> (Check one tern only) [12. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS [38, FRP COMPATIBLE W/l00%METHANOL ❑99.OTIIDR <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-ee 1Ae*,enk El 1. BARE STEEL 0 3. FIBERGLASS/PLASTIC 5. CONCRETE 0 95. UNKNOWN 445 <br /> (Cherkone ncon ody) ❑2. STAINLESS STEEL 04. STEEL CLAD WNIBERGLASS ❑S. FRP COMPATIBLE W1100%METHANOL [199.OTHER_ <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LIMNG EILRUBBERILINED 0 3.EPDXY LINING 0 5.GLASS LINING 0 95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING 8 6UNUNED ❑99 OTHER <br /> (Check we ioun only) (Forbad we only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN ace <br /> PROTECTION R APPLICABLE PROTECTION ❑41NVRESSEDCURRENT ❑99 OTHER <br /> (Checkomtemonly) ❑2 SACRIFICIAL ANODE (Forlacduseanly) <br /> SPILL AND OVERFILL YEARINSTALLED 450 TYPE(bcd me only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Checkeldcmepply) 1ALARM VeedervRoot [13 FILL TUBE SHUT OFF VALVE <br /> ®1 SPILL CONTAINMENT 1990 ®eh Level sensor <br /> ❑2 DROP TUBE ❑2 BALL FLOAT ®4 EXEMPT <br /> ®3STRIKER PLATE Tank Mfg <br /> W.TANK LEAK DETECTION(A dreavuron orthe moneem,nor ceo shell be wbmated m the beet e,a,I <br /> IF SINGLE WALL TANK(Check all that rarely) 453 IF DOUBLE WALL TANK OR TANK WnIf BLADDER(Chwk454 <br /> [:11 VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑11 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE 10 2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4STATISTICAL INVENTORYRECONCILIATION ❑STANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION!PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MOIDAY) 455 1 ESTIMATED QUANTITY O SUBSTANCE REMAINING 45 TANK FILLED WITH INERT MATERIAL? 457 <br /> 12/31/02 Unknown at this time gattong XYes ❑ No Will Be <br /> 1r.i 1..01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.