My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
205
>
2300 - Underground Storage Tank Program
>
PR0231042
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 12:40:42 PM
Creation date
11/2/2018 4:19:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231042
PE
2381
FACILITY_ID
FA0003613
FACILITY_NAME
ARCO STATION #4493*
STREET_NUMBER
205
Direction
N
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13909003
CURRENT_STATUS
02
SITE_LOCATION
205 N CENTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CENTER\205\PR0231042\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
3/2/2012 8:00:00 AM
QuestysRecordID
119110
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION 7 PERMANENTLY CLOSED ON SITE <br /> ONE ITEM E-] 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE R8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: lD5 („) <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNERS TANK I.D.N B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) } [; D. TANK CAPACITY IN GALLONS: �91 OU A <br /> IL TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A Co 1 MOTOR VEHICLE FUEL ❑ 4 OIL a C. to A LAN UNLEADED ❑ 3 DIESEL ❑ 8 AVIATION GAS <br /> 1D PREMRIM UNLEADED ❑ 6 GASAHOL ❑ 7 METHANOL <br /> ❑ 2 PETROLEUM ❑ BD EMPTY ❑ 1 PRODUCT 1c NOGPADE UNLEADED nI`� 5 JET FUEL ❑ 8 M <br /> ❑ 3 CHEMICAL PROOUCT ❑ 95 UNKNOWN ❑ 2 WASTE BS <br /> 2 LEADED L_.J 99 OTHER(DESCRIBE IN ITEM D.BELDYO <br /> D. IF(AI)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A S.e: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B.AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE Of DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SINGLE WALL N A VAULT ❑ 99 OTHER <br /> B. TANK rl I BARE STEEL ❑ 2 STAINLESS STEEL 253 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 8 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 10D% METHANOL COMPATBLE W/FRP <br /> M*MY To) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ I RUBBER LINED ❑ 2 ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 8 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERNAL COMPATIBLE WITH 100%METHANOL7 YES_ NO_ <br /> D.EXTERIOIONR ❑ 1 POLYETHYLENE WRAP [—] 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROS <br /> PROTECTION El 5 CATHODIC PROTECTION ❑ Bi NONE 12K UNKNOWN ❑ 98 OTHER <br /> E.SPILL AND OVERFILL,8M, SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROPTUBE YES NO_ STRIKERPLATE YES_ NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLEPIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A k12 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 9 POLYVINYL CHLORIDE(PVC)A�4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 8 CONCRETE A U 7 STEEL W/COATING A U 8 100%METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION 1 MFCYMat LAE MAK 2 IRE TnxllEsa 3 CmRNNws RNTERsrrML 4 BEC C 121E s AuralwTN Par <br /> ❑ ❑ E3 N9 ❑ IX.TDRNG ❑ �R ❑ 9M WAM ❑ 99 MER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 TANK <br /> RECONCILIATION MONITORING <br /> ❑ 3 MOTORING ❑ 4 GAUGING AUTOMATIC TANK ❑5 MONTORINGWATER ❑ 8 TESTING <br /> ❑ 7 CONTINMONITUOUS INTERSTITIAL ❑RING8 SIR ❑ 9 SETANK GAUGINGNAL ❑10 NINGY TANK ❑ 95 UNKNOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ESTIMATED DALAST U (MO/DAY/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING �' GALLONS INERT MATERIAL? YES ❑ NO <br /> THIS FORM HAS SEEN COMPLETED UNDER PENALTY OF PERJUR O TH E T OF MY KNOWLEDGE,IS TRUEAND CORRECT <br /> TANK OWNERS NAME <br /> (PRINTED&SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NU RS BELOW <br /> COUNTY N JURISDICTION K FACILITY A TANK 8 Q7 <br /> STATE I.D:# m = LLzia-,sl <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DA <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORMA,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETE FOR IN ALLATON .THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PI FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE' -RGROUND STORAGE ANK REGULATIONS <br /> FORM 0 (8-95) 1.0/ _ <br />
The URL can be used to link to this page
Your browser does not support the video tag.