My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 11:49:34 AM
Creation date
11/2/2018 4:30:51 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\BILLING 1988 - 2004.PDF
QuestysFileName
BILLING 1988 - 2004
QuestysRecordDate
9/23/2016 3:15:37 PM
QuestysRecordID
3198799
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA' WATER RESOURCES CONTRO(�ARD <br /> FORM 'B': UNDERtROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION (D <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. -__ � <br /> 2O <br /> MARK ONLY D<1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY OS K <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMI TEMP ARY TA,L.A CLOSURE TNK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: ^� N <br /> Ngo / � /,(� PLAN FARM TANK-YES❑ NO PqCI1 <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY ~ <br /> n^ A <br /> A. OWNERS TANK ID p 3 B. MANUFACTURED BY: <br /> C. YEAR INSTALLED OO D. TANK CAPACITY IN GALLONS. 12 000 <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C N i UNLEADED ❑ 2 LEADED ❑ 3 DIESEL <br /> 3 CHEMICAL PRODUCT ❑ 4 OIL 9 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ BO EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C.&D <br /> A TYPE OF �1 DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEURON ❑ 2 STAINLESS STEEL X3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑ 5 CONCRETE ❑ 6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR F-11 RUBBER LINED ❑ 2 ALKYD LINING X3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENEWPAP ❑2TAR OR ASPHALT E13 VINYL WRAP D4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A 3 UNEDTRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A©4 FIBERGLASS PIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U B 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1 VISUAL CHECK 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS ELECTRONIC MONITOR P 8 5 GROUNDWATER MONITORING WELLS <br /> 6 PRECISION TESTING S 7 PRESSURE TE STING P 8 91 NONE P V 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> I. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY Of F 3. WAS TANK FILLED WITH <br /> /A/a SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> `/ <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TOTHE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) F� �A W DePoL., DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY K FACILITY ID# TANK IO M <br /> © 023 oUo <br /> CURRENT LOCAL AGENCY FACILITY AIDN/JWly APPROVED BY NAME PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> \�V CHECKK PERMIT AMOUNT SURCHARGE AMT. /v FEE CODE RECEIPT# BY: <br /> c 1J <br /> FORMB(6-29-BB) THIS FORM MUST BE ACCOMPANIE YAFACILITY/SITE APPLICATION, FORM `A',UNLESSA RENT FORMA HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page