INSTALLATION INSTRUCTIONS <br /> Read and become familiar with these instructions before doing installation. APR 19 2016 <br /> 1. Install STP per STP/IST Fixed and Variable Length Installation and Owner's Manual. i�/SC'►!1I*I ALC_t <br /> 2. Remove cover of STP-SCI and mount base to wall or other surface. ` W��7I` •:' & W ``°,iW <br /> HYM'�6�1-��'YFr�.ri�e 1 <br /> Note: The STP-SCI must be mounted indoors and can operate at ambient temperatures between 400and1050 F (40-410 <br /> C). <br /> 3. Connect input power of 208-240 VAC to L1 and L2 and Ground wire to terminals per Figure 2. <br /> 4. Connect dispenser hook signal to terminals, 110-250V supply and return per Figure 2. <br /> 5. Using an ohmmeter, verify the motor leads(M1 and M2)are not shorted to ground. <br /> Damage to the STP-SCI may occur if motor leads are shorted together or to ground and power is <br /> Warning A applied. <br /> 6. Connect motor leads to M1 and M2 and Ground wires to terminals per Figure 2. <br /> 7. For Stand Alone controller configuration set SW1 and SW2 poles 1-8 per Figure l(Stand Alone configuration is <br /> Factory setting). For Master-Slave and/or Alternating Circuit configurations, go to "Master-Slave/Alternating <br /> Circuit" section, step 9. <br /> 8. All STP-SCI controllers must be calibrated. Continue to step 14 "Calibration" section to complete installation. <br /> MASTER-SLAVE/ALTERNA TING CIRCUIT <br /> The Master-Slave feature allows the master to turn on additional STP's when the first STP operating needs help due to <br /> loading (flow rate) or an abnormal condition exists. The Alternating Circuit (AC) feature continuously alternates the lead <br /> pump, thus turning on a different STP each time all dispensers are shut off and at least one dispenser is turned back on. <br /> The Master-Slave/AC configuration combines the features of the Master-Slave and AC functions. <br /> I Line leak detection performance can be affected when using multiple STP-SCI's. FE Petro does <br /> Caution Q not recommend using the Alternating Circuit feature in conjunction with electronic line leak <br /> detection. Some electronic line leak detector manufacturers require that the Master turn on first <br /> all of the time. Please refer to the manufacturer's requirements. <br /> Note: STP-SCI is not compatible with the STP-SC or the STP-SCB in Master-Slave,Alternating Circuit configurations. <br /> • Master-Slave will not work with PMA33, PMA75B (50 Hz PMA), or PMAH150B (50 Hz PMA). <br /> • In software revision 1.4 and prior,Alternating Circuit functions the same as a Master-Slave/AC configuration. <br /> 9. Wire STP-SCI controllers according to Figure 3 for Master-Slave, Figure 4 for AC or Figure 5 for Master-Slave &AC <br /> Configurations. Connect Communication cable, RS 485,to terminals(+, G, and —)wire"+"together, "G"together and <br /> together then wire the shielded cable drain wire to Ground (G) at one end only, Use at least 22 AWG three <br /> conductor shielded cable with drain wire. <br /> 10. Connect dispenser hook signal to the STP-SCI designated as Master per Figures 3,4, and 5. <br /> Note: Be sure L1, L2, M1, M2 and Grounds are installed at each STP-SCI. <br /> 11. Configure Master-Slave and Alternating Circuit features by setting SW2 poles 3 and 4 per Figure 1. <br /> 12. Create an address for each controller by setting SW1 poles 1-5 per Table 1. Each Controller must have its own <br /> unique address. <br /> 13. Attach cover of controller to base and complete the"Calibration" section of the installation manual, step 14. <br /> Note: There can only be one Master in a system and up to 31 slaves. <br /> CALIBRATION <br /> Note: Before calibration process can begin, fuel level in tank must be above the motor intake <br /> 1. It is recommended to close either the STP clamp valve or a ball valve at the STP discharge. Turn on power supply to <br /> the STP-SCI. The green light indicator will come on steady, the red light indicator will flash eight times and the <br /> audible alarm will beep eight times. This indicates the STP-SCI is Uncalibrated. <br /> 2. Put the controller in calibration mode by pressing and holding the reset button, the push-button on the right side of <br /> the control box, until all three light indicators blink alternately. This will take approximately 10 seconds. Release the <br /> 3 <br />