My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/26/2022 2:10:29 PM
Creation date
11/2/2018 4:33:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0232352
PE
2361
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
01
SITE_LOCATION
1033 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1033\PR0232352\COMPLIANCE INFO 2016 - 2017.PDF
QuestysFileName
COMPLIANCE INFO 2016 - 2017
QuestysRecordDate
8/8/2018 11:06:32 PM
QuestysRecordID
3201703
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />Facility Name:VANCO TRUCK-AUTO PLAZAFacility Address:1033 W CHARTER WAY, STOCKTON, CA95206 <br />Facility Phone:(209)466-0833 <br />Program:2361 -UST FACILITYInspection Type:ROUTINE INSPECTION -Operating Permit <br />Date:June 20,2018CERS ID:10181461Inspection Contact:Mike Boparai <br /> Consent For:Consent Given By:Mike Boparai, Owner <br />Title:Owner Phone:(209)466-0833 <br />Inspection Photos Samples <br />Underground Storage Tank Program Inspection Report <br />Service Technician Manufacturer's Training:VMI, 12/13/19; VR, 04/06/19 <br />Service Technician Onsite:Joseph Bartholdi Exp.Date:11/17/2019 Designated Operator:Christopher Adams Exp.Date:02/09/2019 <br />R =Repeat violation COS =Corrected on site during inspectioV=ViolationCCR=California Code of Regulations HSC =Health and Safety Code CFR =Code of Federal Regulations <br />File Review <br />101 □ V □ R □ COSFailure to obtain a valid permit to operate from the EHD including but not limited to unpaid feesHSC 25284 <br />102 □ V □ R □ COSNo written agreement between tank owner and tank operator to monitor the tank systemHSC 25284(a)(3)(A)/(B) <br />103 □ V □ R □ COSCurrent financial responsibility documents not submittedHSC 25292.2, 25299.30 <br />104 □ V □ R □ COSUST operating permit application for facility and tank information not submitted or currentCCR 2711 <br />105 ■ V □ R ■ COSFailed to have an approved UST monitoring planCCR 2632(d)(1), 2634(d) <br />106 □ V □ R □ COSFailed to have an approved UST response planCCR 2632(d)(2), 2634(e) <br />107 □ V □ R □ COSPlot plan/site map not submitted or failed to completely show where monitoring is performedCCR 2632(d)(1)(C) <br />108 □ V □ R □ COSFailed to notify the EHD 48 hours prior to conducting testingCCR 2637(f), 2638(e) <br />109 □ V □ R □ COSFailed to test secondary containmentCCR 2637 <br />110 □ V □ R □ COSFailed to submit secondary containment test report within 30 daysCCR 2637(e) <br />111 □ V □ R □ COSFailed to test monitoring and leak detection equipment annuallyCCR 2638(a) <br />112 □ V □ R □ COSFailed to test spill containers annuallyHSC 25284.2 <br />113 ■ V □ R □ COSFailed to submit monitoring system certification test report within 30 daysCCR 2638(d) <br />114 □ V □ R □ COSFailed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut downCCR 2636(f) <br />115 □ V □ R □ COSFailed to submit to EHD notification of designated operator identification or change w/in 30 daysCCR 2715(a) <br />116 □ V □ R □ COSDesignated operator, service tech or installer did not possess current ICC certificationCCR 2715 <br />117 □ V □ R □ COSFailed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years afterCCR 2663(h) <br />118 □ V □ R □ COSFailed to submit tank lining certification within 30 days or to conduct proper testsCCR 2663 <br />119 □ V □ R □ COSDocuments were falsified or misrepresentedHSC 25299(a)(8), 25299(b)(7)120 □ V □ R □ COSFailed to submit UST Certification of Installation/ModificationCCR 2635(d) <br />121 □ V □ R □ COSFailed to submit a written response within 30 days of receiving an inspection reportCCR 2712(f) <br />122 □ V □ R □ COSFailure to submit and maintain UST system component statement of compatibility for substance storedCCR 2631(j)On Site Records <br />201 □ V □ R □ COSFailure to maintain monitoring, maintenance, and follow up action recordsCCR 2712(b) <br />202 □ V □ R □ COSFailed to maintain cathodic protection test records on site for at least 6 1/2 yearsCCR 2712(b) <br />Page 1 of 6 FA0003829 PR0232352 SC001 06/20/2018 <br />EHD 23-01 Rev. 10/31/2017 Underground Storage Tank Program OIR1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjcehd.com
The URL can be used to link to this page
Your browser does not support the video tag.