Laserfiche WebLink
Appendix VI <br />(Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www,waterboards.ca.gov.) <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must <br />be used to document <br />testing <br />and servicing of monitoring equipment. <br />A separate <br />certification or <br />report must be prepared for <br />each monitoring <br />system control panel <br />by the <br />technician who performs the work. A <br />copy of this <br />form must be <br />provided <br />to the tank system <br />owner/operator. <br />The owner/operator must submit a copy of this form to the local agency <br />regulating <br />UST systems <br />within 30 <br />days of test date. <br />A. General information <br />Facility Name: Vanco Truck —Auto Plaza <br />Site Address: 1033 W Charter <br />Facility Contact Person: Mike Boparai_ <br />Make/Model of Monitoring System: TLS 35 <br />B. Inventory of Equipment Tested/Certified <br />Bldg. No.: <br />City: Stockton Zip:95206 <br />Contact Phone No.: (209)466-0833 <br />Date of Testing/Servicing: 6/20/2018 <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every <br />Check the appropriate boxes <br />to indicate specific <br />equipment <br />inspectedlserviced: <br />Tank ID: Diesel North <br />Tank ID: <br />11 <br />In -Tank Gauging Probe. <br />Model: <br />X In -Tank Gauging Probe, Model: MAG <br />X <br />Annular Space or Vault Sensor, <br />Model: 409 <br />a <br />Annular Space or Vault Sensor. <br />Model: <br />X <br />Piping Sump / Trench Sensor(s). <br />Model: 208 <br />U <br />Piping Sump /Trench Sensor(s). <br />Model: <br />X <br />X <br />Fill Sump Sensor(s). <br />Mechanical Line Leak Detector. <br />Model: 208 <br />Model: LD2000 <br />1:1 <br />❑ <br />Fill Sump Sensor(s). <br />Mechanical Line Leak Detector. <br />Model: <br />Model: <br />u <br />Electronic Line Leak Detector. <br />Model: <br />I I <br />Electronic Line Leak Detector, <br />Model: <br />0 <br />U <br />Tank Overfill / High -Level Sensor. <br />Other(specify equipment type and <br />Model: <br />model in Section E on <br />Page 2), <br />U <br />U <br />Tank Overfill / High -Level Sensor. Model: <br />Other(specify equipment t e and model in Section E on Page 2). <br />TankiD: <br />TankiD: <br />0 <br />In -Tank Gauging Probe. <br />Model: <br />u <br />In -Tank Gauging Probe, <br />Model: <br />0 <br />Annular Space or Vault Sensor. <br />Model: <br />U <br />Annular Space or Vault Sensor. <br />Model: <br />0 <br />Piping Sump / Trench Sensor(s). <br />Model: <br />L <br />Piping Sump / Trench Sensor(s), <br />Model: <br />0 <br />Fill Sump Sensor(s). <br />Model: <br />U <br />Fill Sump Sensor(s). <br />Model: <br />Fl <br />Mechanical Line Leak Detector, <br />Model: <br />U <br />Mechanical Line Leak Detector. <br />Model: <br />n <br />Electronic Line Leak Detector. <br />Model: <br />0 <br />Electronic Line Leak Detector. <br />Model: <br />n <br />Tank Overfill ! High -Level Sensor. <br />Model: <br />0 <br />Tank Overffll / High -Level Sensor. <br />Model: <br />0 <br />Other specify equipment type and <br />model in Section E on <br />Page 2), <br />0 <br />Other specify equipment type and model in Section E on Page 2). <br />Dispenser ID: #13/14 <br />Dispenser ID: <br />X <br />Dispenser Containment Sensor(s). <br />Model:208 <br />a <br />Dispenser Containment Sensor(s), <br />Model: <br />X <br />Shear Valve(s). (OPW) <br />0 <br />ShearValve(s). <br />0 <br />Dispenser Containment Floats and <br />Chain(s). <br />U <br />Dispenser Containment Floats and <br />Chain(s), <br />Dispenser ID: #15/16 <br />Dispenser ID: <br />X <br />Dispenser Containment Sensor(s). <br />Model: 208 <br />❑ <br />Dispenser Containment Sensor(s), <br />Model: <br />X <br />Shear Valve(s). (OPW) <br />0 <br />Shear Valve(s). <br />rt <br />Dispenser Containment Float(s) and <br />Chain s . <br />0 <br />Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />Dispenser 10: <br />[:I <br />Dispenser Containment Sensor(s). <br />Model: <br />n <br />Dispenser Containment Sensor(s). <br />Model: <br />() <br />Shear Valve(s). (OPW) <br />n <br />Shear Valve(s). <br />r_I <br />Dispenser Containment Floats and Chains <br />it <br />Dispenser Containment Floats and <br />Chains . <br />C. Certification - I certify that the equipment identified in th <br />tank and dispenser at the facility. <br />s document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />and a Plot Plan showing the layout of monitoring equipment. <br />copy of the report; (check all that apply): ❑ System se -i p <br />Technician Name (print): Ltir f i(�I Signature: -m K <br />Certification No.: I(lrQa (��I <br />information is correct <br />For any equipment capable of generating such reports, I have also attached a <br />n Alarm history report <br />1.6337 <br />License. No.: 1001331 A-HAZ <br />Testing Company Name: ELITE IV CONTRACTORS Phone No.:L209_)_46___„ <br />Testing Company Address: 2535 Wigwam Dr Stockton Ca 95205 Date of Testing/Servicing: 1/11)/ <br />Monitoring System Certification <br />Page 1 of 4 <br />12107 <br />