Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sicehd.com <br /> UNDERGROUND STORAGE TANK (UST)PROGRAM INSPECTION REPORT <br /> Fac.litY Facility - Inspection <br /> Nan.e Address <br /> �_ Date <br /> On Site Records V R COS <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site(V734) <br /> 205 CCR 2712(i) Operating permit not on site(V738) , <br /> 206 HSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame(V737) u <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed(V723) :� n <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months(V722) <br /> 209 CCR 2715(f) Designated operator employee training not performed or log not kept(V727) - -, <br /> 210 CCR 2715(()(2) Unstaffed facility failed to have or implement a training program approved by the EHD(V740) <br /> 211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept(V729) <br /> 212 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept(V728) _ <br /> UST System Observations V R COS, <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release. including spills and overfills(V715) <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003)(V688) n <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004)(V693) u <br /> 304 HSC 25290,1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004)(V695) E n <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained(V694) _ ❑ <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(V691) n <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained(V679) „ <br /> 308 CCR 2636(0 Failed to maintain a continuous monitonng system that activates an audible and visual alarm(V678) <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC(V687) ., <br /> 310 CCR 2636(f)(1) Sensor in a piping sump failed to activate an audible and visual alarm or stop the flow product(V684) c} _ <br /> 311 CCR 2636(0(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs(V683) <br /> 312 CCR 2636 Failed to properly program or operate leak detection equipment(V677) <br /> 313 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced(V681) <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003)(V758) <br /> 315 HSC 25290.2(c)(1) Primary containment not tight(Jul 2003-Jun 2004)(V759) „ <br /> 316 HSC 25290.1(c)(1) Primary containment not tight(after Jun 2004)(V822) „ <br /> 317 HSC 25290.1. <br /> 25290 2, 29291 Secondary containment not tight(V710) <br /> - <br /> 318 CCR 2636(a) Failed to have secondary containment(V706) <br /> 319 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003)(V821) <br /> 320 HSC 2 C)l3 1(c)(3), <br /> 25290.2 c Secondary containment not constructed to prevent water intrusion(V707) r <br /> 3x21 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump(V709) u <br /> 322 CCR 2636(f)(2) Line leak detector not installed(V700) -, n <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi(V704) - <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty(V712) <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons(V714) <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements(V716) <br /> 327 CCR 2635(b)(2) Overfill prevention system was overridden(V845) <br /> 328 HSC 25283.5 Unburied below grade UST failed to meet exemption status(V739) - o <br /> 329 CCR 2717,1(g) Tampered with red tag(V742) n <br /> Received Inspea%r <br /> By(in@ial): Vnibal. <br /> EHD 23-01 REV 08/07/15 Page 2 UST INSPECTION REPORT <br />