My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1234
>
2300 - Underground Storage Tank Program
>
PR0500941
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 1:55:23 PM
Creation date
11/2/2018 4:39:12 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0500941
PE
2381
FACILITY_ID
FA0004940
FACILITY_NAME
CASE POWER & EQUIPMENT
STREET_NUMBER
1234
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16320004
CURRENT_STATUS
02
SITE_LOCATION
1234 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\1234\PR0500941\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
5/21/2012 8:00:00 AM
QuestysRecordID
116268
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNI/ WATER RESOURCESCONTRO' 'OARD _ <br /> FORM `B': UNDEffGROUND STORAGE TANK PROGRAM ` <br /> TANK TANK PERMIT APPLICATION INFORMATION ' $� <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY 1 NEW PERMIT ❑ 3 RENEWALPERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED T K <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED Q/ <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 341 /C FARM TANK-YES❑ NO z <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY /� 9SZL IO <br /> A. OWNERSTANKIDp B. MANUFACTURED BY: <br /> C. YEAR INSTALLED ID. TANK CAPACITY IN GALLONS: D J <br /> w <br /> II. TANK PONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED, PLETE ITEM D. co <br /> A. 101 MOTOR VEHICLE FUEL ❑ 2 PETROLEUMB. C. 1 UNLEADED 1--]2 LEADED ❑ 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT F-] 4 OIL 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑ 5 HAZARDOUS ❑ BO EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.# C.A.S.#� <br /> XIII. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,8 D <br /> A.TYPE OF 1,41OUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEELCLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE 7 ALUMINUM ❑ 0100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZ®STEEL UNKNOWN ❑99 OTHER <br /> C. INTERIOR <br /> ❑ 1 RUBBERUNED ❑2 ALKYD LINING ❑3 EPDXY LINING F7 JIIfiENOUCUNING <br /> EY9LINING ❑ 5 GLASS LINING ❑6 UNLINED 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ I POLYETHIENEWRAP ❑2 TAR OR ASPHALT ❑ INYE WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE VuNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B.CONSTRUCTION A 11 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 UNED TRENCH U 95 UNKNOWN A U W OTHER <br /> A U 1 STEELARON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE <br /> C. MATERIAL A U 5 ALUMINUMA 6 CONCRETE A U 7 STEELCLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL U 5 UNKNOWN A U W OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR 8 FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> / S 1 VISUAL CHECK 8 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> ( P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE UST USED(MO/YR) 2. ESTIMATED QUANTITY Of 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING INOALLONB INERT MATERIAL? E]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> [jM = = lolol / lokelLl ? loo <br /> CURRENT LOCAL AGENCY FACILITY IDN P OVEO BY E PHONE M WITH AREA CODE <br /> PERMIT NUMBERR T9APPROVAL ATE PERMIT EXPIRATION DATE <br /> 9- ?-15V <br /> +A/I CHECK# PERMIT AMOUNT SURCHjkRGE AMT. FEE CODE RECEIPT# BY: <br /> �J FORM B(3 7-B8) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORM W HAS BEEN FILED <br /> ' COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.