My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
939
>
2300 - Underground Storage Tank Program
>
PR0504011
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 3:20:15 PM
Creation date
11/2/2018 4:51:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504011
PE
2381
FACILITY_ID
FA0006051
FACILITY_NAME
NOMELLINI CONSTRUCTION COMPANY
STREET_NUMBER
939
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323046
CURRENT_STATUS
02
SITE_LOCATION
939 W CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHARTER\939\PR0504011\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
3/13/2012 8:00:00 AM
QuestysRecordID
115630
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNP WATER RESOURCES CONTRA 'OARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PRGTMAM <br /> TANK TANK PERMIT APPLICATION INFORMATION Qp <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Z <br /> 10 <br /> MARK ONLY r-11 NEWPERMIT- ❑3 RENEWALPERMIT ❑5 CHANGE OF INFORMATION PERMANENTLYC SEDTA <br /> ONE ITEM ❑ 2INTERIM PERMIT 4 AMENDEDPERMIT ❑ 6 TEMPORARY TANK CLOSURE. V8 TANK REMOVED oq <br /> o Ca <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED:73? FARM TANK-YES❑ NO ® N <br /> N <br /> I. ANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY (� <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: —4 <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK ONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D <br /> B. <br /> 1 UNLEADED <br /> 1 EL <br /> 1 MOTOR VEHICLE <br /> ID <br /> A ❑3 CHEM CAL PROD CTL ❑ 4 OILROLEUM LJ 1 PRODUCT C ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 60 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑T METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARKONE ITEM ONLYIN BOXA,B.C,AD <br /> A.TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLEWALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEELPRON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑ <br /> MATERIAL 8100%METHANOL COMPATIBLE FRP <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR F-11 RUBBER LINED ❑ 2 ALKYD UNING ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ IS UNING MATERIAL COMPATIBLE WITH 100%MEMMOL? ❑YES ❑ NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHUNE WRAP ❑ 2 TAR OR ASPHALT ❑ 3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑91 NONE ❑ 95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A SINOIE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> U STEEL/IRON A U 2 STAINLESSSTEEL U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE U T STEEL CLAD W/FRP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S I VISUALCHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1.ESTIMATED DATE UST USED(MO/YR) 2.ESTIMATED OUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> j <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK IO# <br /> O a oy <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT# BY: <br /> \V FORM B(6-29-88) THIS FORM MUST BE ACCOMPANIL A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A C ENT FORMA' HAS BEEN FILED <br /> nATA Donn=-- -Yr <br />
The URL can be used to link to this page
Your browser does not support the video tag.