My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
1045
>
2300 - Underground Storage Tank Program
>
PR0501746
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 3:23:25 PM
Creation date
11/2/2018 4:52:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0501746
PE
2381
FACILITY_ID
FA0009124
FACILITY_NAME
Wild Horses Motorsports
STREET_NUMBER
1045
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
Ln
City
Lodi
Zip
95240
CURRENT_STATUS
02
SITE_LOCATION
1045 S Cherokee Ln
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\1045\PR0501746\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
6/27/2012 8:00:00 AM
QuestysRecordID
127337
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA' WATER RESOURCES CONTROI )ARD <br /> FORM `B': UNDEkGROUND STORAGE TANK PROGRAM f ' <br /> TANK TANK PERMIT APPLICATION INFORMATION .o <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. _ <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWALPERMIT ❑5 CHANGE OF INFORMATION ❑F-�I�7 PERMANENTLY CLOSED TANK 10 <br /> ONE ITEM 1-12 INTERIM PERMIT ❑4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE L�TANK REMOVED <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: a Ll Y S FARM TANK-YES❑ NO <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY 0) <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: <br /> C. YEARINSTALLED D. TANK CAPACITY IN GALLONS: <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> F-] 1 MOTOR VEHICLE <br /> FUE <br /> A L F-13 DIESEL <br /> 3 CHEMICAL PRODUCT ❑4 OIL PETROLEUM B D LEADED <br /> 1 PRODUCT C ❑4 GASAHOL ❑5 JETFUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑ 2 WASTE ❑7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,8 D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEELARON ❑2 STAINLESS STEEL ❑3 FIBERGLASS ❑4 STEEL CUD W/FIBERGLASS REINFORCED PLASTIC <br /> BMATERLU F-1 5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑7 ALUMINUM E]8100%METHANOL COMPATIBLE FRP <br /> TAN <br /> [-]9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C.INTERIOR ❑ I RUBBER LINED ❑2ALKYD LINING ❑3EPDXY LINING Q tPHENOLIC UNING <br /> LINING ❑ 5 GLASS LINING ❑6 UNLINED - \ ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES -NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYEMLENE WRAP ❑ 2 TARORASPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELMON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD WEEP A U 8100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUALCHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P 8 5 GROUNDWATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN GALLONS INERT MATERIAL? ❑YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID N TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> canezaex D <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> CHECKN PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPTR BY: <br /> FORM B S 29-66) THIS FORM MUST BE ACCOMPANIEC'BY A FACILITY/SITE APPLICATION, FORM `A',UNLESS A CURRENT FORMA HAS BEEN FILED <br /> DATA PROCESSING COPY <br />