BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
225
>
2300 - Underground Storage Tank Program
>
PR0231314
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2024 4:48:58 PM
Creation date
11/2/2018 4:58:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231314
PE
2361
FACILITY_ID
FA0003615
FACILITY_NAME
ARCO STATION #760*
STREET_NUMBER
225
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04314048
CURRENT_STATUS
02
SITE_LOCATION
225 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\225\PR0231314\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
6/19/2012 8:00:00 AM
QuestysRecordID
124767
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
112
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CAUFORNIA '-• .o <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION MANENTLY CLOSED ONSITE <br /> ONE REM 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ZIg TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-SPECIFY IF UNKNOWN <br /> A. OWNERS TANK I.D.0 //' B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MOIDAYHEAR) K D. TANK CAPACITY IN GALLONS: 2 D <br /> ILTANKCONTENTS IFA-11SMARKED.COMP RELIC. <br /> A. ED MOTOR VEHICLE FUEL 4 OIL B. 0' ❑ tAREGULAR UNLEADED B 3 DIESEL E] g AVIATION GAS <br /> 4 GASAHOL <br /> ❑ 2 PETROLEUM ❑ BO EMPTY ❑ 1 PRODUCT ❑ ibPREMIUMUNLEADEO 5 JETFUEL ❑ 7 METHANOL <br /> E:] 3 CHEMICALPRODUCT ❑ 95 UNKNOWN WASTE ❑ 2 LEADED �N OTHER (DESCRIBE IN REM D. BELOW) <br /> 0. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED /,Yj�Gf)-�' i '- C.A.S.S: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOX <br /> A. TYPE OF ❑-I-POUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER E:] 95 UNKNOWN <br /> SYSTEM 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANIQ ❑ 99 OTHER <br /> B. TANK SARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W1 FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ g IW% METHANOL COMPATIBLE WIFRP <br /> (PrimMyTmk) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ❑ 2 ALKYO LINING ❑ XY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING ❑ 6 UNLINED 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> 19 LINING MATERIAL COMPATIBLE WTTH 100% METHANOL? YES_ NO— <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE 96 UNKNOWN ❑ 99 OTHER <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND.BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE AXCA-?GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH Ajf}6 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 RARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 0 CONCRETE A U 7 S/T�EE-�LVUCOATING A U B 100% METHANOL COMPATIBLEW/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A(VN UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑ 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING ❑ 31MMTERORMG ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VAPOR MONITORING n4TOMATK:TANK GAUGING❑ 5 GROUND WATER MONUTORING <br /> ❑ 6 TANK TESTING [:] 7 INTERSTRIALMONRORING ❑ 91 NONE 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED( V1Yfi) 2 ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> NjA1O>�° SUBSTANCE REMAINING ///`� GALLONS IN <br /> MATERIAL YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> APPLICANTS NAME DATE <br /> IPNNTEU A SIGNATURE) <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY 9 JURISDICTION 9 FACILITY* TANK x <br /> STATE I.DA o ( i lql <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERMIT EXPIRATION DATE Tr- <br /> FORMS <br /> •'SFORMS (9.90) THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION•FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. <br /> FORM84W <br /> Ik✓ <br />