My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
3535
>
2300 - Underground Storage Tank Program
>
PR0231800
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 3:55:22 PM
Creation date
11/2/2018 5:04:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231800
PE
2381
FACILITY_ID
FA0003687
FACILITY_NAME
OLD TRUCK STOP, THE
STREET_NUMBER
3535
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
13206009
CURRENT_STATUS
02
SITE_LOCATION
3535 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\3535\PR0231800\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
7/2/2012 8:00:00 AM
QuestysRecordID
128638
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA �J 1 <br /> STATE WATER RESOURCES CONTROL BOARD " '" •'_c M1a <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE f FORMFOREACH TANK SYSTEM.MARK ONLY ❑ 1 NEW PERMIT [:] 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ ] PERMANENTLY CL BED ON SITE <br /> l ONE REM ❑ 2 INTERIM PERMIT F76 AMENDED PERMIT 8 TEMPORARY TANK CLOSURE O 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS— SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.t B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYNEAR) D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A �1 MOTOR VEHICLE FUEL ❑ d OIL B. C. 1a REGULAR UNLEADED 3 DIESEL ❑ 8 AVIATION GAS <br /> 2 PETROLEUM ❑ SO EMPTY' �1 PRODUCT ❑ 10 PREMIUM UMFADEO d GASAHOL ❑ T METHANOL <br /> ❑ is MIDGRADE UNLEADED 5 JETFUEL ❑ B M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED 99 OTHER(DESCRIBE IN REM D.BELOWI <br /> 0. IF(At)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B,AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR UNEP ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ a STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE 8 POLYVINYL CHLORIDE ❑ T ALUMINUM ❑ B 100% METHANOL COMPATIBLE WIFRP <br /> (PNm ry Tank) ❑ 9 BRONZE 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ I RUBBER UNED 2 ALKYD UNING ❑ 3 EPDXY UNING ❑ 6 PHENOLIC UNING <br /> LINING OR ❑ 5 GLASS UNING ❑ UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS UNING MATERIAL COMPATIBLE WITH 1 METHANOL? VES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 CO TING ❑ 3 VINYL WRAP ❑ d FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODICPROTECTION ❑ 91 NO ❑95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL,etc. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES_ NO_ STRIKER PLATE YES NO_ DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND ORIF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U N FLEXIBLE PIPING A U 99 OTHER <br /> S. CONSTRUCTION A U 1 SINGLE WALL A U 2 DOUBLE WAL\ U 3 UNED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U I BARE STEEL A U 2 STAINLESS STE A U 3 POLYVINYL CHLORIDE(PVC)A U N FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U fi CONCRETE A U T STEEL W/COATING A U 8 100% METHANOL COMPATIBLE WIFRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U /O CATHODIC PROTEC ON A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTIONM I IaaWae¢Ime LEN( 2 1.KE ncxm>:.ss 3 coxlwuaus BEcmaMc uuE s To <br /> .c'L. ❑ <br /> ❑ 9FIEmOB ❑ TESTING YONfOPAln ❑ DAK nE1E4TOR ❑ Swi00WN 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 RECONCILIATIONNUAL INVENTORY ❑ 3 VADOZEMONITORING ❑ A AUTOMAnGAUGING C TANK ❑ 5 GROUND WATER <br /> ❑ 8 ANNUALTESTING <br /> ❑ T <br /> MONITORINGINTERSTITIAL ❑ 8 SIR ❑ 9 TAWEEKLY <br /> NEK LY MANUAL 10 MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> G TESTING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> i.ESTIMATED ATE LAST USED(MOAIAV/YFI? 2 ESTIMATED OUANRTY OF 3.WAS TANK FILLED WITH <br /> �$Li SUBSTANCE REMAINING ALLONS INERT MATERIAL? VES ❑ NO ❑ <br /> THIS F RM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE ST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> (PRINTED d SIGNANRET <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW D a 3 If cQ <br /> COUNTY 0 JURISDICTION# FACILITY k!'�,7 3 6.:1'�� TANK A <br /> STATE LD:# T-Fd O 4/ ! <br /> PERMIT NUMBER PERMIT APPROVED BVA]ATE PERMIT E%PIRATION DATE <br /> PERMIT NUMBER —TER 1 <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APP' ION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. 'C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING n,, GROUND STORAGE TANK REGULATIONS <br /> FORM B (695) _! /_ Y <br />
The URL can be used to link to this page
Your browser does not support the video tag.