My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
3535
>
2300 - Underground Storage Tank Program
>
PR0231800
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 3:55:22 PM
Creation date
11/2/2018 5:04:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231800
PE
2381
FACILITY_ID
FA0003687
FACILITY_NAME
OLD TRUCK STOP, THE
STREET_NUMBER
3535
STREET_NAME
CHEROKEE
STREET_TYPE
RD
City
STOCKTON
Zip
95205
APN
13206009
CURRENT_STATUS
02
SITE_LOCATION
3535 CHEROKEE RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\3535\PR0231800\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
7/2/2012 8:00:00 AM
QuestysRecordID
128638
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
92
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD o <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION -FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. SII <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED I <br /> OBA OR FACILITY NAME WHERE TANK IS INSTALLED: , <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNERS TANK I.D.R B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAYIYEAR) 0. TANK CAPACTTY IN GALLONS: QV <br /> II.TANK CONTENTS IFA-1 IS MARKED,COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE EL ❑ 4 OIL B. C. ❑ le REGULAR UNLEADED Q 3 DIESEL ❑ B AVIATION GAS <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT lb PREMUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ It MOGRADE UNLEADED 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PROD1 ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 cnnm g 99 07HER(M RIBENREMDBELOM <br /> 0. IF(A1)IS NOT MARKED, ENTEk NAME OF SUBSTANCE STORED C.A S R: <br /> 111. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.S.AND C,AND ALL THAT APPLIES IN BOX 0 AND E <br /> A. TYPE OF ❑ 1 DOUBLEALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE W ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK ❑ 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CIAO W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ B 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ 2 ALKYD UNING ❑ 3 EPDXY LINING ❑ 4 PHENOUC LINING <br /> LINING OR ❑ 5 GLASS LINING ❑ 8 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPO BLE WITH 100% METHANOL? YES_ NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE ❑ 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> E SPILL AND OVERFILL,8L0. SMLLCONTAINMENTIN ALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLEn(YEAR) <br /> DROP TUBE VES NO_ STRIKER PLATE YES_ NO_ DISPENSER CONTAINMENT VES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IFA VE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A k ZDOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U CONCRETE A U 7 STEEL W/COATING A U B 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 1 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑1 �0 �Lv�LAK ❑2 T ❑a CONM"1d°°"°°nnN' C:]4 BBCIWJMC U ❑5 w 71c PUP 99 o7H8R <br /> OElE4T0A iB51NG 1KNTOBNA LTAK 9E1ECfOR 9A11991Yn <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 RC-CONCMANUALIUATIN pRY 3 MO BORING ❑ 4 GAUGING AUTOMATIC TANK ❑5 MONITORING GROUND WATER ❑ e ANNUAL <br /> GTANK <br /> ❑ 7 MONITORING INTERSTITIAL ❑ 8 SIR 9 WEEKLY <br /> LY MANUAL ❑10 GING MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-P E) <br /> 1.E TE DATE LAST USE ( AY/YR) 2 ESTIMATED OUA TY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE RE INING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN C MPLETED UNDER PENALTY OF PEq3VRY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DATE <br /> 'PRINK OnER NPE7 l J <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW7;1� 'T-b l / <br /> COm JURISDIC'nONI_L�JR FACIL—!�W TOANKR V `( <br /> STATE LD:# <br /> PERMIT NUMBER PERMIT APPROVED SYAMATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT AP' TION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED, -M C MUST BE COMPLETED FOR INSTALLATIONS THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLO 1. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING TGROUND STORAGE TANK REGULATIONS <br /> U;LATIONS <br /> FORM (6-95) • -4 11 .5 , ! v <br />
The URL can be used to link to this page
Your browser does not support the video tag.