Laserfiche WebLink
• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.orQ/ehd/unitiii.html <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility Plaza Liquors#1 Fadrea g00 S. Cherokee Ln. Lodi, CA Inspection Mar 14, 2012 <br /> Name: q Address: Date: <br /> Fadldy TNe: <br /> Ce,,,�,; Abrar Ahmed & Ashok Kumar Co-owner 4§) 368-0127 <br /> Inspection XRoutine XMonitoring System Certification n Installation ii Complaint—IDK: ❑Omer: <br /> Type: <br /> (Authority HSC 25289) Abrar Ahmed Ashok Kumar Co-owner <br /> Consent for. Xlnspectiorm XSampling XPhotos Granted by..Abrar <br /> Monitoring Piping XPressunzed o Suction 0 Gravity Overfill p{Mechanical ❑Audible/visual <br /> Panes Gllbarco EMC System: Prevention: <br /> UST 4 5 6 <br /> Product 87-octane 91-octane_. _._.DSL_._ <br /> opertl <br /> ator Alex Jabbari IbCaC,eE: p. 10-2-12 Violations: M1-Release Detection U M2-Release Prevention n M3—Bom <br /> onSite :ce ICC Exp Manufacturer's <br /> Technician: David Winkler 3-5-14 ning: vmi 11-10-13, swrcb 3-31-14, yr 2-13-14 <br /> VIOLATIONS <br /> # C1 I C2 M I Code Section HSC=California Health and Safety Cade;CCR=California Code of Regulations <br /> Cl=Class 1 Nolation:C2=Class 2 violation:M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 26404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tank system <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plaNsite map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(1)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 X HSC 25291(1) Annual line leak detector test not performed (M1) <br /> 111 X HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (112) <br /> pertnit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily dose UST system not obtained <br /> 120 HSC 25298(c) Permit to Gose UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 JCCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> lnepc . ReceN By: Title: <br /> Aris Cacapit (209) 468-3453 5 -(Ll� ,�_ <br /> EHD 23-02 Rev 09/01/11 Page 1 UST INSPECTION REPORT <br />