0 0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility plaza Li uor#1 Facility 800 S. Cherokee Ln. Lodi, CA Inspection Mar 25, 2014 <br /> Name: q Address: Dale: <br /> VIOLATIONS <br /> # Cl C2 FM I Code Section HSC=CA Health and Safe Code;CFR=Cade of Fetleral Re Mations <br /> C1=Class 1 violation;C2=Class 2 vicla[iorc,M=Minor violation <br /> On Site Records(continued) <br /> E302 <br /> X CCR 2715(c) Designated operator monthly inspection:(1)alarms not documented;(2-4)spill containers,UDCs,and sumps <br /> if necessary)not inspected; 5 required test dates not checked or noted; 6 employee trainingnot verified <br /> CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months <br /> CCR 2715(f) Designated operator employee training:(1)not performed;(2)not current for at least one employee on site; <br /> 3 to not kept <br /> HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept <br /> Observations <br /> HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills <br /> HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary containment(M7) <br /> 303 CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the eadiest opportunity (Mt) <br /> 304 CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST Will <br /> 305 CCR 2636(f)(1) Failed to maintain a continuous monitoring system for underground piping&UDCs that activates an (Mt) <br /> audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br /> 306 CCR 2631(a) Primary containment is not product tight <br /> 307 HSC 25291(a)(2) Secondary containment for UST system is not tight <br /> 308 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br /> 309 CCR 2631 Failed to have secondary containment for piping(includes conventional suction piping) (Mz) <br /> 310 HSC 25291(a) Water in 2-containment not removed,analyzed&properly disposed of <br /> 311 CCR 2636(f)(2) Line leak deter or(s)not installed or failed to detect a 3-gallon per hour leak at 10 psi (M1) <br /> 312 CCR 2635(b) No spill container or overfill prevention system installed (Mz) <br /> 313 CCR 2635(b)(1) Spill container failed to contain a minimum capacity of five gallons,or failed to provide a means to keep (M2) <br /> the spill container empt <br /> 314 CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements (Mz) <br /> 315 HSC 25299(f)(2) Tampering with or disabling leak detection devices or alarms <br /> 316 CCR 2631.1(a) UST system is not compatible with the substance stored <br /> 317 HSC 25298(a) Illegally abandoned UST system <br /> AB 1702(2003-2004)HSC25290.2(installed between 07/01103 and 06130/04) <br /> VPH Systems HSC 25290.1 installed on or after 07/01104 <br /> Compatibility and permeability requirements:(a)UST system is not compatible with the substance stored;(b) <br /> 401CCR 2631.1 results of the compatibility and permeability testing requirements listed in subsections CCR 26311 and(d) <br /> for a UST system installed after Jul 1,2004,were not submitted <br /> 402 HSC 25290.1(c)(1)HSC 25290.2 c1 Primary containment not liquid or vapor tight <br /> 403 HSC 25290.1(c)(2 <br /> HSC 25290.2(c)(2)) Secondary containment not liquid or vapor tight <br /> 404 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> #407 <br /> HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment,or the entry of <br /> HSC 25290.2 d li uid or va or from the rima containment into the seconds containment <br /> of HSC 25290.1(e) Interstitial liquid measurement method,constant vacuum,or constant pressure in the interstitial space the <br /> UST s stem not maintained <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use:(1)Enhanced leak detection; (2)inert gas <br /> HSC 25290.2 ressure test a roved by SWRCB; 3 test method deemed equivalent to 1 or(2)by the SWRCB <br /> Emergency Generator Systems <br /> 501 1 1 1 CCR 26361 Emergency generator monitoring system not checked daily or log not kept if no leak detector (M1) <br /> 502 1 1 1 HSC 25281.5(b)(3) Unburied fuel piping not visually inspected at least monthly or log not kept (M1) <br /> i in a Vault <br /> 601 HSC 25283.5(a)(1) All exterior surfaces of the tank and connected piping cannot be directly viewed <br /> 6024 HSC 25283.5(a)(2) Structure that the UST is located in does not provide for secondary containment <br /> 603 HSC 25283.5(a)(3) Failed to conduct weekly UST inspections or maintain a log of weekly inspections <br /> 604 HSC 25283.5(a)(5) UST installed after July 1,2003,does not meet or exceed applicable sections of HSC 25291 <br /> Non-Pressurized Piping <br /> 701 CCR 2643(d) Daily monitoring of suction piping(pre-January 1, 1984)not performed (M1) <br /> Inspector: Received By: Title: <br /> Aris Cacapit (209) 468 3453 <br /> EHD 23-02 Rev 04/22/13 Page 2 UST INSPECTION REPORT <br />