My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2009 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
800
>
2300 - Underground Storage Tank Program
>
PR0231325
>
COMPLIANCE INFO 2009 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/3/2022 1:47:12 PM
Creation date
11/2/2018 5:16:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009 - 2015
RECORD_ID
PR0231325
PE
2361
FACILITY_ID
FA0003997
FACILITY_NAME
PLAZA LIQUOR #1
STREET_NUMBER
800
Direction
S
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04742004
CURRENT_STATUS
01
SITE_LOCATION
800 S CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHEROKEE\800\PR0231325\COMPLIANCE INFO 2009 - 2015 .PDF
QuestysFileName
COMPLIANCE INFO 2009 - 2015
QuestysRecordDate
3/28/2017 7:00:00 PM
QuestysRecordID
3360547
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
APR12 ,,, Appendix VI <br /> l 6WITORING SYSTEM CERTIFICATION <br /> ENVip For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chap %W,lipp�IL afretty Code; Chapter 16, Division 3,Title 23,California Code of Regulations <br /> This form must be used to document testing and g of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: PLAZA LIQUORS 2 Bldg.No.: <br /> Site Address: 800 S CHEROKEE LANE City: LODI Zip: 95242 <br /> Facility Contact <br /> Person: TOM Contact Phone No.: (0) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 03-29-13 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: 87 Tank ID: DIE <br /> 2 In-Tank Gauging Probe. Model: MAG 1 2 In-Tank Gauging Probe. Model: MAG 1 <br /> 2 Annular Space or Vault Sensor. Model: 420 2 Annular Space or Vault Sensor. Model: 420 <br /> 2 Piping Sump/Trench Sensor(s). Model: 208 2 Piping Sump/Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 2 Mechanical Line Leak Detector. Model: LD 2000 2 Mechanical Line Leak Detector. Model: LD 2000 <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> 2 Tank Overall/High-Level Sensor. Model: FLAPPER 2 Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(spedfy equipment type and model in Section E on Page 2). <br /> TanklD: 91 TanklD: <br /> 2 In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> 2 Annular Space or Vault Sensor. Model: 420 SPLIT W I DIE ❑ Annular Space or Vault Sensor. Model: <br /> 2 Piping Sump/Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ?❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> 2 Mechanical Line Leak Detector. Model: LD 2000 ❑ Mechanical Line Leak Detector. Model: <br /> fr <br /> CElectronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> n Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> 2 Shear Valve(s). 2 Shear Valve(s). <br /> 2 Dispenser Containment Float(s)and Chain(s). 2 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Senscr(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shearvalve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment <br /> ❑ Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): 2 System set-up 2 Alarm history report <br /> Technician Name(print): FELIX RAMIREZ Signature: - <br /> Certification No.: 5273934-UT License No: 08-1740 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)7440113 <br /> Testing Company Address: 416 2"0 STREET GALT CA 95832 Date of Testing/Servicing: 03-29-13 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br /> SSC 15 <br />