My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHERRYLAND
>
2827
>
2300 - Underground Storage Tank Program
>
PR0502350
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/28/2021 10:33:58 PM
Creation date
11/2/2018 5:23:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0502350
PE
2381
FACILITY_ID
FA0005411
FACILITY_NAME
LARSON & RISHWAIN
STREET_NUMBER
2827
Direction
N
STREET_NAME
CHERRYLAND
STREET_TYPE
AVE
City
STOCKTON
Zip
95205
CURRENT_STATUS
02
SITE_LOCATION
2827 N CHERRYLAND AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CHERRYLAND\2827\PR0502350\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
7/3/2012 8:00:00 AM
QuestysRecordID
135694
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'B': UNDERGROUND STORAGE TANK PROGRAM ' <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. Z <br /> IC) <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWALPERMIT ❑5 CHANGE OF INFORMATION n 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM F-12 INTERIM PERMIT F-] 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE �[L B RANK REMOVED/a 6 N <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: 3a /6 FARM TANK-YES❑ NO A <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIF p <br /> A. OWNERS TANK ID# B. MANUFACTUREDBY: <br /> C. YEARINSTALLED ` D. TANK CAPACITY IN GALLONS. -6,010 <br /> II. TANK qONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUMB. C. 1 UNLEADED ❑2 LEADED [D3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑4 GASAHOL ❑5 JET FUEL ❑ 6 AVIATION GAS <br /> [:] 5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,A D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR UNER ❑ 95 UNKNOWN <br /> SYSTEM [:j 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> MATERIAL ❑ 9 BflONZE ❑ 10 GALVANIZED STEEL ❑ 95.ANKI GOWN -]99 OTHER <br /> C. INTERIOR ❑ 1 RUBBERLINED ❑2 ALKYDUMNG ❑ 3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED ❑95 UNKNOWN <br /> ❑ ISUNING MATERIAL COMPATIBLE WITH 100%METRANOL? ❑YES ❑ NO ❑990THER <br /> D.CORROSION ❑ I POLYETHLENE WRAP 2 TAROBASPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION 9/ NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEELIIRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P 8 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P 8 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES GALLONS ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> o I a I a= I of C) <br /> CURRENT LOCAJ_AGENCY FACILITY IDNaAPPROVED BY NAM qYI� PHONE#WITH AREA CODE <br /> � � � <br /> PERMIT NUMBER PERMIT APPROVAL DATE PE MIT EXPIRATION DATE <br /> CHECK N PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT k BY: J <br /> \NTLI FORM B(6-29-m) THIS FORM MUST BE ACCOMPANIED eY A FACILITY/SITE APPLICATION, FORM `A',UNLESS A ..ENT FORMA' HAS BEEN FILED i <br /> DATA. PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.