My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2015 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1340
>
2300 - Underground Storage Tank Program
>
PR0529124
>
COMPLIANCE INFO_2015 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 2:22:42 PM
Creation date
11/2/2018 5:38:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2015 - 2018
RECORD_ID
PR0529124
PE
2351
FACILITY_ID
FA0019437
FACILITY_NAME
ARCO am/pm # 83230
STREET_NUMBER
1340
Direction
W
STREET_NAME
COLONY
STREET_TYPE
Rd
City
Ripon
Zip
95366
APN
261-590-110-000
CURRENT_STATUS
01
SITE_LOCATION
1340 W Colony Rd
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COLONY\1340\PR0529124\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
10/26/2016 3:50:54 PM
QuestysRecordID
3092866
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
263
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rf� <br /> �. oSAN JOAQUIN COUNTYENVIRONMENTAL HEALTH DEPARTMENT <br /> � j�f l 1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br /> cP. Telephone:(209) 468-3420 Fax:(209) 468-3433 Web:www.sioov.org/ehd <br /> 4(t FOM1� <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> Arco -AM Pk x- 31-I <br /> Facility Address: Service Request#: <br /> 4 1 D vel CA SRQ015q0lI <br /> Onsite Service Technician's Name: ICC Service Technicianfinstaller Exp.Date: Manufacturer Training: <br /> e �C _5_ uk - <br /> SERVICE SERVICE <br /> Leak detector <br /> ❑ mechanical Model: Spill bucket ❑ minimum 5 gallon <br /> ❑ ❑ electronic Serial #: ❑ ❑ 1 hour hydrostatic ❑ Incon TS-STS <br /> ❑ line test programmed ❑ Caldwell System ❑ Other <br /> Leak detector Spill bucket ❑ minimum 5 gallon <br /> ❑ El mechanical Model: ❑ ❑ 1 hour hydrostatic L1 Incon TS-STS <br /> ❑ electronic Serial #: <br /> ❑ line test programmed ❑ Caldwell System ❑ Other <br /> sensor Primary piping testing at: <br /> ❑ positive shutdown Model: <br /> ❑ ❑fail safe Serial #: ❑ psi <br /> ❑ NA minutes <br /> sensor Secondary containment testing for: <br /> ❑ ❑ positive shutdown Model: UDC(s) Piping <br /> ❑ fail safe Serial #: Sump(s) UST(s) <br /> ❑ NA <br /> sensor ❑ Testing for the above components are next due by: <br /> ❑ ❑ positive shutdown Model: <br /> ❑fall safe Serial #: Note Please be aware that 2°containment components are required to be tested upon <br /> ❑ NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention (see LG letter 150-1) Other: see below Vl <br /> ❑ This UST facility is APPROVED to operate ElThis UST facilityQ-V is N T APPROVED to�ofYbtoperateQL Oe-(ane <br /> Ovs't +,e 'Lw;, r-Lle IN - k1 Skku-,- couare$e ob eL-- <br /> a lus e RsI;.>vvo4 L- 31 <br /> Ct" SW o r -{4e&ded aud &Qryed " f-v\nc-Q N <br /> V. O <br /> "V\5 Awkk PA 4eas 64AQQ C Q M- <br /> i AA, tcueallled <br /> J�o U,LS Q <br /> e gctjsl ' <br /> THIS FACILITY IS SUBJECT T REINSP CTION AT XNY TIME AT EHD'§ CURFAENY HOURLY RATE. <br /> EHD Insp Receiv ByY7 Titl <br /> EHD 23-04 UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 4/30/12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.