Laserfiche WebLink
FIED PROGRAM CONSOLIDATED FO <br /> UNDERGROUNDSTORAGETANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (One form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections 7,H,,II/,/V,and IX below) 430 <br /> ❑ 1.NEW PERMIT ® 3.RENEWAL PERMIT ❑ 5.CHANGE OF INFORMATION <br /> ❑ 6.TEMPORARY UST CLOSURE ❑ 7.UST PERMANENT CLOSURE ON SITE ❑ S.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 430. 1 DATE EXISTING UST DISCOVERED: 430b. <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) - <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3 <br /> Chevron Station#210997 <br /> BUSINESS SITE ADDRESS 103, CITY 104 <br /> 1442 A Colony Drive Ripon, CA 95366 <br /> II. TANK DESCRIPTION <br /> TANK ID# 432. TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> 1 XERXES ® 1.A STAND-ALONE TANK Compine one page for each <br /> ❑ 2.ONE IN A COMPARTMENTED UNIT compartment in the unit. <br /> DATE UST SYSTEM INSTALLED 435- TANK CAPACITY IN GALLONS 436. NUMBER OF COMPARTMENTS IN THE UNIT 437. <br /> 01/16/2003 20,000 0 <br /> III. TANK USE AND CONTENTS <br /> TANK USE 9 la.MOTOR VEHICLE FUELING ❑ Ib.MARBNA FUELING ❑ Ic.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Inllud.s Used Oil) ❑ 5.EMERGENCY GENERATOR FUEL[HSC§252815(1)] <br /> ❑ 6.OTHER GENERATOR FUEL [1 95.UNKNOWN _ .❑,99 OTHER(Specify): 439a. <br /> .-.. _.__......,_ ........ ...-...-. ._ _. <br /> CONTENTS PETROLEUM: ® la.REGULAR UNLEADED ❑ lc MIDNLE <br /> GRADE UADED ❑ Ib PREMNM UNLEADED 440, <br /> El <br /> El3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> ❑.8.PETROLEUM BLEND FUEL ❑ 9 OTHER-PETROLEUM� cif,). 440a <br /> NON-PETROLEUM:❑ 7.USED O - <br /> IL ❑ 10 ETHANOL <br /> ❑ 11.OTHER NON-PETROLEUM(Specify): 440b. <br /> IV. TANK CONSTRUCTION <br /> _TYPE OF TANK ❑ 1 SINGLE WALL ® 2 DOUBLE WALL ❑ 95 UNKNOWN 441 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 3.FIBERGLASS ❑ 6.INTERNAL BLADDER <br /> 07.STEEL+INTERNAL LINING [1 95.UNKNOWN [199.OTHER(Specify) 444a <br /> DARY <br /> SECONCONTAINMENT ❑-1.STEEL ®3.FIBERGLASS ❑ b EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445. <br /> ❑ 90:-NONE,.,..,.__-.-._❑ 95 UNKNOWN 99 OTHER(Specify): 445a. <br /> OVERFILL PREVENTION ® I AUDIBLE&VISUAL ALARMS ❑ 2.BALL FLOAT ® 3.FILL NBESHUT-OFF VALVE 452. <br /> ❑ 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION EQUIPMENT <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION ❑ 1.SINGLE WALL ® 2.DOUBLE WALL ❑ 99 OTHER <br /> SYSTEM TYPE ® t PRESSURE ❑ 2 GRAVITY ❑ 3 CONVENTIONAL SUCTION ❑ 4 SALE SUCTION[23 CCR§2636(a)(_3)] 458. <br /> PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIB-ERGLASS ❑ 8 FLEXIBLE ❑ 10.RIGID PLASTIC 464: <br /> ❑.90_NONE ❑ 95.UNKNOWN ❑ 99 OTHER(Specify): 464.. <br /> .-.-. _ .._-.... ....._- . _F _...... .-.____... _____.-.-_ ........ . ......... <br /> SECONDARY CONTAINMENT ❑ 1.STEEL ® 4 FIBERGLASS ❑ 8 FLEXBLE ❑ 10.RIGID PLASTIC 464b. <br /> ❑ 90.NONE ❑ 95 UNKNOWN ❑ 99 OTHER(Specify): 464° <br /> ..... ___- __. .._..... ........-.. ....... _-'-._.._. ....__,_.------' __-.._.. ......... <br /> PIPING/TURBINE CONTAINMENT SUMP TYPE ® I SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d. <br /> VI. VENT,VAPOR RECOVERY (VR) AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ® L STEEL [14.FIBERGLASS [1 10.RIGID PLASTIC El 90.NONE [I99.OTHER(Specify): 4°bg64ej <br /> VENT SECONDARY CONTAINMENT ❑ I STEEL ❑ 4 FIBERGLASS ❑ 10 RIGIDPLASTIC ® 90.NONE ❑ 99.OTHER(Specify): 464H <br /> ........_..___. <br /> .__ ....-.....-_.._ -__ .._.__ ... <br /> VR PRIMARY CONTAINMENT ❑ 1 STEEL ® 4 FIBERGLASS ❑ 10 RIGID PLASTIC ❑ 90:,NONE ❑ 99..,OTHER(Specify): qbe <br /> ........_.- ._ ... ......---. <br /> VR SECONDARY CONTAINMENT ❑ L STEEL ❑ 4 FIBERGLASS ❑ 10 RIGID PLASTIC ® 90.NONE ❑ 99.OTHER(Specify): q4" <br /> VENT PIPING TRANSITION SUMP TYPE ❑ L SINGLE WALL ❑ 2.DOUBLE WALL ® 90.NONE <br /> ..._-...___. ....____.-__.. ___..._-__ .-._........._ _ ._._.... ....__-._. .. ..-.___..__ <br /> RISER PRIMARY CONTAINMENT ® I.STEEL ❑ 4 FBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify) 4642. <br /> RISER SECONDARY CONTAINMENT ❑ 1.STEEL [14.FIBERGLASS [110.RIGID PLASTIC ® 90.NONE [399.OTHER(Specify): g64k1 _ <br /> FILL COMPONENTS INSTALLED ® 1.SPILL BUCKET ® 3 STRIKER PLATEMOTTOM PROTECTOR ® 4.CONTAINMENT SUMP 451a--., <br /> VII. UNDER DISPENSER CONTAINMENT (UDC) <br /> CONSTRUCTION TYPE 9 1.SINGLE WALL ® 2,DOUBLE WALL 0.3 NO DISPENSERS ❑ 90 NONE 409.. <br /> _.. ............._..._..____. ..... - -- - --- <br /> -.._EEL-- ......-.-.-- ......-....... ..-.-.-.-__ ------'-'- .-.-.-.-.- <br /> CONSTRUCTION MATERIAL ❑ I STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 99 OTHER(Specify) Obgb' <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT ❑ 6.ISOLATION "a. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I cery that tis UST system is compatible with the hazardous substance stored and that the information provided herein is true, <br /> accu ie,an till compliance with legal requirements. <br /> APPLICANT SIGNATURE: DATE 06/10/2009 °'� <br /> APPLICANT NAME(print) Che ron roducts Co./JIM HARTMAN 471. APPLICANT TITLE Retail HES Pelmet Desk 472 <br /> UPCF UST-B Rev.(12/2007) <br />