My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 4:22:35 PM
Creation date
11/2/2018 5:52:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COLONY\1442\PR0518458\BILLING 2002 - 2005.PDF
QuestysFileName
BILLING 2002 - 2005
QuestysRecordDate
6/18/2018 10:29:20 PM
QuestysRecordID
3917788
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
U ED PROGRAM CONSOLIDATED FORIJP <br /> PRESUBMITTAL TANK <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> VI.PIPING CONSTRUCTION(check all that a Page 4 of 4 <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE ®1.PRESSURE D 2.SUCTION D 3.GRAVITY 458 ❑1.PRESSURE D 2. SUCTION [13.GRAVITY 459 <br /> CONSTRUCTION ❑1.SINGLE WALL [13.LINED TRENCH [:199.OTHER 460 ❑I.SINGLE WALL D 95.UNKNOWN 462 <br /> MANUFACTURER ®2.DOUBLE WALL [195.UNKNOWN 2.DOUBLE WALL D 99.OTHER <br /> MANUFACTURER AO Smith 461 MANUFACTURER 463 <br /> D 1.BARE STEEL D 6.FRP COMPATIBLE w/loo°/. METHAFrDI. D 1.BARE STEEL D 6.FRP COMPATIBLE W/tm S METwwOL <br /> D 2.STAINLESS STEEL D 7.GALVANIZED STEEL D Unknown D 2. STAINLESS STEEL D 7.GALVANIZED STEEL <br /> [13.PLASTIC COMPATIBLE W/CONTENTS ❑99. Other D 3. PLASTIC COMPATIBLE W/CONTENTS ❑8.FLEXIBLE(HDPE) D 99. OTHER <br /> ®4.FIBERGLASS D 8.FLEXIBLE(HDPE) D 4. FIBERGLASS ❑9.CATHODIC PROTECTION <br /> [15.STEEL W/COATING [19.CATHODIC PROTECTION 464 D 5. STEEL W/COATING ❑95.UNKNOWN 465 <br /> VII.PIPING LEAK DETECTION(Check all that apply)(A description ofthe monitoring progam shall be submitted to the bcal enc.) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466 SINGLE WALL PIPING 467 <br /> PRESSURIZED PIPING(Chock all that apply): PRESSURIZED PIPING(Check all that apply) <br /> ❑1.ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP SHUT D 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION+ <br /> AUDIBLE AND VISUAL ALARMS. AUDIBLE AND VISUAL ALARMS. <br /> ❑2.MONTHLY 0.2 GPH TEST [12. MONTHLY 0.2 GPH TEST <br /> ❑3.ANNUAL INTEGRITY TEST(0.1GPH) D 3.ANNUAL INTEGRITY TEST(0.1GPH) <br /> D 4. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> [15.DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING [15. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALUES IN BELOW GROUND PIPING): D 6. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> D 7.SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW D 7. SELF MONITORING <br /> D 9.BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> [IS. DAILY VISUAL MONITORING <br /> [19. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSORVLTH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> ®a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS D a AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> ®b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM D b AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> Dc. NO AUTO PUMP SHUT OFF Dc NO AUTO PUMP SHUT OFF <br /> ®11. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT D 11 AUTOMATIC LEAK DETECTOR <br /> OFF OR RESTRICTION <br /> ®12. ANNUAL INTEGRITY TEST(0.1 GPH) D 12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> D 13. CONTINUOUS SUb1P SENSOR+AUDIBLE AND VISUAL ALARMS [113. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> [114. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF• [114. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> D 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITHOUT FLOW [115. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> SHUT OFF OR RESTRICTION <br /> [116.ANNUAL INTEGRITY TEST(0.1 GPH) [116.ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [117. DAILY VISUAL CHECK D 17. DAILY VISUAL CHECK <br /> VIIL DISPENSER CONTAINMENT <br /> DISPENSER CONTAINMENT D I.FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE D 4.DAILY VISUAL CHECK <br /> DATE INSTALLED 468 ®2.CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS D 5.TRENCH LINER/MONITORING <br /> 2003 ®3.CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR [16.NONE 469 <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> IX.OWNER/OPERATOR SIGNATURE <br /> I certify that he information pmvide cin' rad wmt th at of my knowledge. <br /> SIGNATURE OF O P DATE 470 <br /> QR.L7E9R April 24,2003 <br /> NAME OF OWNER/OPERJrrORbriK TITLE OF OWNER/OPERATOR 472 <br /> Chevron Products Company/D.R. ERI Retail ESH Specialist <br /> Permit Number(For local use only) 473 Permit Approved(For local use only) Permit Expiration Date(For local use only) 475 <br /> UPCF(1/99 revised) 176 Formerly SWRCB Form B <br />
The URL can be used to link to this page
Your browser does not support the video tag.