My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 4:22:35 PM
Creation date
11/2/2018 5:52:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COLONY\1442\PR0518458\BILLING 2002 - 2005.PDF
QuestysFileName
BILLING 2002 - 2005
QuestysRecordDate
6/18/2018 10:29:20 PM
QuestysRecordID
3917788
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
55
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a <br /> *IED PROGRAM CONSOLIDATED F010 <br /> UNDERGROUND STORAGE TANKS - TANK pAGE 1 Es� AL TAIVI�s <br /> /A 06�5 211 o (two pages per tank) <br /> TYPE OF ACTION ®1 NEW SITE PERMIT 4 AMENDED PERMIT P&""`I° 4 <br /> ❑ ❑ 5 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE I '1 <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE 1 <br /> ❑ 3 RENEWAL PERMIT (Specifyrrnson-forlocal_emly) (SPecifyte_on-forlocal_eonly) ❑ 8 TANK REMOVE <br /> BUSINESSNAME(same_FAca1TYNAMEor DBA-Doing Bosineea As) o <br /> Chevron Station#210997 3 FACILITY ID: 0 0 0 0 0 0 0 0 0 0 0 1 <br /> LOCATION WITHIN SITE(Optiand) <br /> L TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) 431 <br /> rU <br /> ID# 43z TANK MANUFACTURER 433 COMPARTMENTALIZED TANK E]Yes ® No 434 <br /> �L"'RXE`S If-Yes'. <br /> --Plate one Page for each compamnrnt. <br /> INSTALLED(YEAR/MO) a3s TANK CAPACITY IN GALLONS a36 NUMBER OF COMPARTMENTS <br /> t Install 20,000 4J7 <br /> 0 <br /> ONAL DESCRIPTION(For local use only) <br /> 99&Colony Drive,Ripon CA 95366 438 <br /> IL TANK CONTENTS <br /> ANK USE 439 PETROLEUM TYPE <br /> OTOR VEHICLE FUEL ®la. REGULAR UNLEADED 44.❑2. LEADED ❑5. JET FUEL <br /> complete Peo-olrnm Type) ❑16 PREMIUM UNLEADED 3. DIESEL❑ ❑6. AVIATION FUEL <br /> ON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHEREMICAL PRODUCT COMMON NAME (fmm Hazerdars Materals le,,on ry page) 441 CAS#(from Haanrde_Mazcnals Invento 442 <br /> ZARDOUS WASTE ry pass)d«Used Oil) REGULAR UNLEADED 800-61-9 <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL ❑3. SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> 02. DOUBLE WALL [34. SINGLE WALL IN VAULT ❑99. OTHER_ <br /> TANK MATERIAL-primary rank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC Ll 5. CONCRETE <br /> ❑95. UNKNOWN 444 <br /> (Check ane item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS E18 FRP COMPATIBLE W/100%METHANOL ❑99.OTHER_ <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL ®3. FIBERGLASS/PLASTIC ❑5. CONCRETE ❑95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑B. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER_ <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LINING ®6 UNLINED ❑99 OTHER <br /> (Chack one item only) <br /> (For local use only) <br /> OTHER CORROSION ❑1 MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN 448 448 <br /> PROTECTION IF APPLICABLE PROTECTION ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE <br /> SPILL AND OVE (For local use only) <br /> RFILL YEARINSTALLED 45u TYPE(lacal_.only) 451 OVERFILL PROTECTION EQUIPMEN 1:YEAR INSTALLED 452 <br /> (Check all rhaz apply) ® I SPILL CONTAINMENT ®1 ALARM Remote <br /> 2002 Overfill AudibleNisual Alarm ❑3 FILL TUBE SHUT OFF VALVE <br /> 2 DROP TUBE ®2 BALL FLOAT <br /> OPW53VML-3180 ❑4EXEMPT <br /> ®3 STRIKER PLATE Tarek <br /> IV.TANK LEAK DETECTION(A description ofthe monitoring program shall be submined he the local agency.) <br /> IF SINGLE WALL TANK(cne.k all amt apply) 453I1DOUBLE WALL TANK OR TANKWITHBLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) (Check one item only) <br /> ❑5 MANUAL TANK GAUGING(MTG) ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER <br /> ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER_ <br /> 1V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 056 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(1/99 revised) 173 Fonnerly SWRCB Form B <br />