Laserfiche WebLink
D PROGRAM CONSOLIDATED FOIJ <br /> PRESUBMF1'I'AL TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 <br /> (two pages per tank) <br /> P e'1 4 <br /> TYPE OF AMON R 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT [35 CHANGE OF INFORMATION ❑ 6 TEMPORARY SITE CLOSURE \ l.� <br /> (Check one item only) ❑ 7 PERMANENTLY CLOSED ON SITE <br /> C13 RENEWAL PERMIT (speci%ras <br /> eon-forinedosawly) (Specilyreuon-forkom <br /> nalonly) C] STANK REMOVED o <br /> BUSINESS NAME(Sameas FACRMNAMEor DBA-Doing Business As) 3 FACILITY ID: 0 0 0 0 0 - 0 0 0 0 0 off <br /> Chevron Station#210997 R° <br /> LOCATION WITHIN SITE(Optional) 431 <br /> I.TANK DESCRIPTION (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> 1 XERXES If"Yes",complete one page for each compamnrnt. <br /> DATE INSTALLED(YEAR/MO) 415 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> Target Install 7/l/02 20,000 0 <br /> ADDITIONAL DESCRIPTION(Fm local use only) 438 <br /> Hwy 99&Colony Drive,Ripon CA 95366 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ®1. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifinerked complete Peackem Type) ❑lb. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION FUEL <br /> [12. NON-FUEL PETROLEUM ❑to. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER_ <br /> 03. CHEMICAL PRODUCT COMMON NAME (front award. Mazenials I--any page) 441 CAS#(from Brocade.Materials inventory page) 442 <br /> ❑4. HAZARDOUS WASTE <br /> (Inemdes Used Oil) REGULAR UNLEADED 800-61-9 <br /> ❑95.UNKNOWN <br /> III. TANK CONSTRUCTION <br /> TYPE OF TANK ❑1. SINGLE WALL [:13. SINGLE WALL WITH ❑5. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95. UNKNOWN <br /> ®2. DOUBLE WALL ❑4. SINGLE WALL IN VAULT ❑99. OTHER_ <br /> TANK MATERIAL-primary tank ❑1. BARESTEEL ®3. FIBERGLASS/PLASTIC S. CONCRETE 095. UNKNOWN 444 <br /> (Checkonc item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FE3ERGLASS ❑S. FRP COMPATIBLE W/100516 METHANOL [199-OTHER_ <br /> REINFORCED PLASTIC(FRP) <br /> TANK MATERIAL-secondary tank ❑1. BARE STEEL 9 3. FIBERGLASS/PLASTIC ❑S. CONCRETE ❑95. UNKNOWN 445 <br /> (Check one item only) ❑2. STAINLESS STEEL ❑4. STEEL CLAD W/FIBERGLASS ❑8. FRP COMPATIBLE W/100%METHANOL ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑10.COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING [195.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING ❑2 ALKYD LINING ❑4 PHENOLIC LTMNG ®6 UNLINED ❑99 OTHER <br /> (Check one item only) (For local use only) <br /> OTHER CORROSION ❑I MANUFACTURED CATHODIC ®3 FIBERGLASS REINFORCED PLASTIC ❑95 UNKNOWN a48 448 <br /> PROTEMON IF APPLICABLE PROTECTION ❑4IMPRESSED CURRENT ❑99 OTHER <br /> (Check one item only) ❑2 SACRIFICIAL ANODE (For loan[we only) <br /> SPILL AND OVERFILL YEAR INSTALLED 450 TYPE(local we only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Checkdl thaz apply) ®ISPn.L CONTAINMENT NI ALARM Remote <br /> 2002 Overfill AudibleNisual Alarm ❑3 FILL TUBE SHUT OFF VALVE <br /> 2 DROP TUBE ®2 BALL FLOAT ❑4 EXEMPT <br /> ❑ OPW 53VML-3180 <br /> ®3 STRIKER PLATE Tank Mfg <br /> IV.TANK LEAK DETECTION(A description ofthe monitoring prognam shall be submined to the local agency.) <br /> IF SINGLE WALL TANK(check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> (Check one item only) <br /> ❑I VISUAL(EXPOSED PORTION ONLY) ❑5 MANUAL TANK GAUGING(MTG) ❑1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2 AUTOMATIC TANK GAUGING(ATG) ❑6 VADOSE ZONE ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3 CONTINUOUS ATG ❑7 GROUNDWATER ❑3 MANUAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑8 TANK TESTING <br /> (SIR) BIENNIAL TANK TESTING ❑99 OTHER <br /> IV.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF(1/99 revised) 173 Formerly SWRCB Form B <br />