EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COMSTOCK
>
12585
>
2300 - Underground Storage Tank Program
>
PR0540523
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/22/2021 10:21:07 PM
Creation date
11/2/2018 6:01:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0540523
PE
2381
FACILITY_ID
FA0017285
FACILITY_NAME
WATERLOO ORCHARDS
STREET_NUMBER
12585
STREET_NAME
COMSTOCK
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08915036
CURRENT_STATUS
02
SITE_LOCATION
12585 COMSTOCK RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COMSTOCK\12585\PR0540523\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/2/2012 8:00:00 AM
QuestysRecordID
139506
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFOR' 16 WATER RESOURGE$,CON_ D' OARD <br /> FORM B': UNDEIfMROUND STORAGE TANK PROGRAM <br /> TANKTANK PERMIT APPLICATION INFORMATIONTANK. Z <br /> ' <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH <br /> i0 <br /> MARK ONLY ❑ I NEW PERMIT ❑3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE TANK REMOVIED—�"cQ y CN <br /> FACILITY/SITE NAME WHERE/TANK IS INSTALLED: A//'j FARM TANK-YES L (,V <br /> GTl <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY <br /> A. OWNERS TANK ION B. MANUFACTURED BY: <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: <br /> 11. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. ❑ 1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑2 LEADED ❑ 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑4 OIL ❑ 1 PRODUCT ❑ 4 GASAHOL ❑ 5 JET FUEL ❑ 6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑95 UNKNOWN ❑ 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.N C A.S.N'. <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C.A D <br /> A TYPE OF ❑ 1 DOUBLE WALLED ❑ 3 SINGLE WALLED WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑2 SNGUWAILED ❑ 4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEL/IRON ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8 100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> ❑ 1 RUBBER LINED ❑2 ALKYD LINING ❑ 3 EPDXY LINING ❑4 PHENOUC LINING <br /> C.INTERIOR <br /> LINING ❑5 GLASS LINING F-]fi UNLINED E]95 UNKNOWN <br /> ❑ ISLINING MATERIAL COMPATIBLE WITH 100%METHANOL? YES ❑ NO ❑ 99 OTHER <br /> D.CORROSION ❑ I POLYETHLENE WRAP ❑2 TARORASPHALT ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑5 CATHODIC PROTECTION ❑91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U I SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE IPVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P 8 1 VISUAL CHECK P 8 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P 8 6 PRECISION TESTING P 3 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> L ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OF 3. WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? [:]YES ❑ NO <br /> 4,%UONB <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 6 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY N JURISDICTION M AGENCY N FACILITY ID N TANK ID N <br /> E � <br /> CURRENT LOCAL AGENCY FACILITY41 a APPROVED BY NAMISE PHONE N WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMITIRAT NDATE <br /> CHECK• PERMIT AMOUNT SURCHARGE AMT. FEE CODE RECEIPT N BY: <br /> FORM B(6-29-86) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORM W HAS BEEN FILED <br /> DATA PROCESSING COPY <br />
The URL can be used to link to this page
Your browser does not support the video tag.