Laserfiche WebLink
STATE OF CALIFORNIA +I <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B ;r <br /> 1 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT a 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION O 7 PERMANENTLY CLOSED ON SITE <br /> ONE REM ❑ 2 INTERIM PERMIT O 4 AMENDED PERMIT 8 TEMPORARY TANK CLOSURE B TANK REMOVED .['1 <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: F V <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A OWNER'S TANK I.D.Y B. MANUFACTURED BY: <br /> C. DATE INSTALLED(MO/DAY/YEAR) D. TANK CAPACITY IN GALLONS: 3 O <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> A. 1 MOTOR VEHICLE FUEL ED OIL B. C. ❑ 1a REGULAR UNLEADED ❑ 3 DIESEL ❑ 8 AVIATION GAS <br /> F-] 2 PETROLEUM ❑ BO EMPTY �1 PRODUCT ❑ It, PREMIUM UNLEADED ❑ 4 GASAHOL 7 METHANOL <br /> 1c MIDGRADE UNLEADED O 5 JET FUEL ❑ B M85 <br /> O 3 CHEMICAL PRODUCT 95 UNKNOWN 2 WASTE 2 LEADED O 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(p1)IS NOT MARKED. ENTER NAME OF SUBSTANCE STORED C.A.S.0: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A B AND C,AND ALL THAT APPLIES IN BOX D AND <br /> A. TYPE OF ❑ 1 DOUBLE WALL F--j 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEMI�2 SINGLE WALL F-14 SINGLE WALL IN A VAULT 99 OTHER <br /> B. TANK z 1 BARE STEEL O 2 STAINLESS STEEL F7 3 FIBERGLASS O 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL '❑ 5 CONCRETE ❑ 8 POLYVINYL CHLORIDE ❑ 7 ALUMINUM 8 100% METHANOL COMPATIBLE W/FRP <br /> (PNMMTank) ❑ 9 BRONZE O 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C INTERIOR ❑ 1 RUBBER UNED O 2 ALKYD LINING 3 EPDXY LINING O 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING Z2�l8 UNLINED 95 UNKNOWN 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 10D% METHANOL? YES_ NO <br /> D.EXTERIOR O 1 POLYETHYLENE WRAP O 2 COATING ❑ 3 VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION 91 NONE 9S UNKNOWN Q 99 OTHER <br /> E.SPILL AND OVERFILL,BLC. SPILL CONTAINMENT INSTALLED(YEAR) OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> DROP TUBE YES NO_ STRIKER PLATE YES_ NO DISPENSER CONTAINMENT YES_ NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION U 1 SINGLE WALL A U 2DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A 5 ALUMINUM A U 8 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION ❑i IEDN4MfAL LYIE 15AIL ❑2 UNE mxT M ❑3 w9lm WS NTDLS ❑4 M=KHc UK C:]5 mroMmc mw 99 OTHER <br /> DETECTOR TESTNO MONiOfffiIG LEAK 9ETELTCR $1111TODNN <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 RECONCILIATION NUAL INVENTORY 3 MONIITORING OZE ❑ 6 AUTOMATIC <br /> IC TANK 5 GROUND MONITORING <br /> ❑ 8 ANNUAL TESTING <br /> ❑ 7 <br /> MONITORING INTERSTITIAL 8 SIR ❑ 9 TANKKLY MANUAL ❑10 MONTHLY TANK 95 UNKNOWN ❑99 OTHER <br /> TING <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PUCE) <br /> 1.ESTIMATED DATE T USEL�1( O/D Y/YR) 2 ESTIMATED QUANTITY OF �" 3.WAS TANK FILLED WITH YES ❑ <br /> SUBSTANCE REMAINING e GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> TANKERS NAME DATE <br /> (PRINTED651BNA <br /> TURET <br /> LOCAL AGENCY USE ONLY THE STATE LD.NUMBER IS COMPOSED OF THE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# NK 0 <br /> STATE 01 <br /> PERMIT NUMBER PERMIT APPROVED BYIDATE PERM <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLAN. FILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE UNDERGROUND STORAGE TANK REGULATIONS <br /> FOX <br /> i rt{695�7 9 1< S- j 2- Y 1/-4%6 <br />