My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2022 1:21:44 PM
Creation date
11/2/2018 6:03:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\BILLING.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
78
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQULPCOUNTY ENVIRONMENTAL HEALIEPARTMENT <br /> 1868 E.Hazelton Ave. • Stockton,CA 95205-6232 • Phone(209) 468-3420 <br /> Donna Heran,R.E.H.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED UNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE Only for"Permit Status" identified as IN COMPLIANCE <br /> Program Permit Permit <br /> Record ID Number Program Code and Description Permit Status: <br /> Valid <br /> PRO627682 PT0019329 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY IN COMPLIANCE 1/1/2015 To 12/31/2015 <br /> Hazardous Waste Generator Program <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code,Div.20, Chap.6.5,Art.2-13, <br /> Sec.25100 at seq,and Title 22,California Code of Regulations,Chap.20: _ <br /> PR0231066 2300-UNDERGROUND STORAGE TANK FACILITY <br /> Underground Storage Tank Program• <br /> California Health and Safety Code,Div.20,Chap.6.7 and Title 23,California Code of Regulations,Chap. 16: _ <br /> P/E Tank# Tank Record ID Permit# Capacity Contents Permit Status System Type Leak Detection Permit Valid <br /> 2362 2 390002310660504887 PT0007490 10,000 DIESEL INCOMPLIANCE DOUBLE-WALL Continuous Monitoring 1/1/2015 To 12/31/2015 <br /> BOE ID#: 44041281 <br /> Underground Storage Tank Permit Conditions <br /> I) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid and/or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain die operating permit,the owner and operator shall comply with the H&S Code,Div,20,Chap.6.7 and 6.15;and CCR,Title 23,Chap.16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued to a person other than the owner or operatorofthe tank,the Pemiittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Environmental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the permit. <br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monitoring equipment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7) In the event of spill,leak,or other unauthorized release,the Pemiitee shall comply with the requirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be available for inspection for a period of at least three years from the date the monitoring was <br /> performed. <br /> 9) The EHD shall be notified of any change in ownership or operation ofthe UST system within 30 days of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in tank contents or usage),the Permit to Operate will be subject to review,modification or <br /> revocation. <br /> 11) Construction,repair and/or removal permits are required from the EHD prior to any change,repair or removal of UST system equipment. <br /> 12) This Permit to Operate shall not be considered permission to violate any laws,ordinances or statutes of any other Federal,State or Local agency. <br /> 13) _A"Conditional"Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> .....--_.-_............... ............_........_...----------_._..._"--"------...-_.__- ..._....-...........'_--------`--------------------- -------------------------------. <br /> PERMITS TO OPERATE may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: SPRINT <br /> DBA: SPRINT COMMUNICATIONS CO LP <br /> Tank Owner: SPRINT CORPORATE <br /> CERSID 10151123 <br /> Regulated Facility: SPRINT UNITED MANAGEMNT CO. FacilitylD FA0003819 <br /> 3807 CORONADO AVE Account to AR0003406 <br /> STOCKTON CA 95204 Issued 3/19/2015 <br /> Billing Address: <br /> SPRINT WEST EHS TERRITORY MANAGER <br /> P.O. BOX 7994 <br /> SHAWNEE MISSION KS 66207 <br /> 7023.rpt' <br />
The URL can be used to link to this page
Your browser does not support the video tag.