My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO_2016 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/2/2018 6:07:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2017
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2016 - PRESENT.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Sprint United Managemnt Co. 3807 Coronado Ave, Stockton November 03, 2016 <br /> On Site Records <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site ❑V n R u COS <br /> 205 CCR 2712(i) Failure to have an approved UST response plan available onsite ❑V ❑R n COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions ❑V u R ❑COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment u V u R ❑COS <br /> 208 CCR 2650(e) Failed to notify the EHD of a reportable unauthorized release ❑V ❑R ❑COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed ❑V o R ❑COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months in V in R ❑COS <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept u V ❑R ❑COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD ❑V ❑R ❑COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑V ❑R ❑COS <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ❑V n R o COS <br /> UST System Observations <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills n V n R ❑COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) n V u R u COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) u V ❑R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) u V ❑R ❑COS <br /> 305 HSC 25290.1(a) VPH monitoring of the interstitial spaces of the UST system is not maintained ❑V ❑R u COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity ❑V ❑R ❑COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained u V u R ❑COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm a V ❑R ❑COS <br /> 309 CCR 2636(f)(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product ❑V u R u COS <br /> 310 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs ❑V n R n COS <br /> 311 CCR 2638(a),2641() Failed to properly program or operate leak detection equipment u V in R ❑COS <br /> 312 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced ❑V ❑R u COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight ❑V u R u COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight u V ❑R ❑COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ❑V ❑R ❑COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) u V ❑R ❑COS <br /> 25290.2(c3) <br /> 317 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R u COS <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V u R u COS <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty ❑V u R u COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements ❑V o R u COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status ❑V ❑R ❑COS <br /> FAD003819 PR0231066 SCO01 11/03/2016 <br /> EHD 23-01 Rev.09/22/16 Page 2 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.