My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2010 - 2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2010 - 2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 6:07:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010 - 2015
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2010 - 2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
212
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system controlyanel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: Sprint Stockton Bldg.No.: <br /> Site Address: 3807 Coronado Ave City: Stockton Zip:95204 <br /> Facility Contact Person: Doye Contact Phone No.: (217 )663-9440 <br /> Make/Model of Monitoring System:Veeder-Root.TLS 300C Date of Testing/Servicing: 11 f 8 12013 <br /> E. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to incl€tate specific equipment inspected/serviced: <br /> Tank ID: Diesel AST 5000 Gal Tank ID: <br /> ®In-Tank Gauging Probe, Model: Mag 1 ❑ In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: 794390420 El Annular Space or Vault Sensor. Model: <br /> OPiping Sump/Trench Sensor(s), Model: 794380-208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> LJ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ©Tank Overfill/High-Level Sensor. Model:Flapper I V-R Ext Alarm ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify cqui ment a and model in Section E on Fa a 2). ❑ Other(specify equipment ty a and model in Section L on Paxe 2 . <br /> Tank ID: Diesel UST 10060 Gal Tank ID: <br /> ®ln-Tank Gauging Probe. Model: Mag 1 ❑ In-Tank Gauging Probe. Model: _ <br /> ❑O Annular Space or Vault Sensor. Model: 794380-302(Brine) ❑ Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model:794380-208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s). Model: <br /> Cl Mechanical Line Leak Detector. Model: _ ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> OTank Overfill/High-Level Sensor. Model:Flapper/V-R Ext Alarm ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment ri e and model in Section E on Page 2). ❑ Other(specify equipment type anci madel in Section E on Page 2)f <br /> Sunup ID:AST Trans sump Dispenser ID: <br /> ❑ Sump Containment Sensor(s). Model:_794380-208 ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s), Cl Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain s). ❑ Dispenser Containment Floats and Chains <br /> Dispenser ID: Dispenser ID: - <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). U Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s), ❑ Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: Dispenser 1D: <br /> ❑ Dispenser Containment Sensor(s). Model: _ ❑ Dispenser Containment Sensar(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Float(s)and Chain(s). ❑ I]is enser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form, Include information for every tank and dispenser at the facility. <br /> C. Cer tifiCation -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> enrrect and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(cheek all that apply): x System - x Alarm history report <br /> Technician Name(print):Peter Jauregui III Signature: ` <br /> f <br /> Certification No.:_B34641 License.No.: 708231 <br /> Testing Company Name:_Jauregui&Culver inc. _ Phone No.: (760) 743-0518 <br /> Site Address:959 W.mission Ave Escondido CA 92025 Date of Testing/Servicing:_1l_/_20_/20 1 3 <br /> Page 1 of 03/01 <br /> Monitoring System Certification <br />
The URL can be used to link to this page
Your browser does not support the video tag.