Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited..Chapter 6.7,Health and Safety Code; Chapter 16,,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared <br /> for each monitoring system control panel by the technician who performs the work. A copy of this form must he provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 <br /> days of test date. <br /> A. General Information <br /> Facility Name: Sprint Stockton Bldg No.:_ 1 <br /> Site Address: 3807 Coronado Ave City:Stockton Zip:95204 <br /> Facility Contact Person: Doye Contact Phone No.:(217 )663-9440 <br /> Make/Model of Monitoring System:Veeder-Root TLS 300C Date of Testing/Servicing: 11/8 12012 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the approprlate boxes to indicates eeirle equipment Inspected/serviced: <br /> Tank ID: Diesel AST 5000 Gal Tank ID: <br /> 121n-Tank Gauging Probe. Model: Mag I ❑ In-Tank Gauging Probe. Model: <br /> EEAnnular Space or Vault Sensor. Model: 794390-420 ❑ Annular Space or Vault Sensor. Model: <br /> �KlPiping Sump/Trench Sensor(s). Model: 794380-208 ❑ Piping Sump/Trench Sensor(s), Model: <br /> ❑ Fill Sump Sensor(s). Model: ❑ Fill Sump Sensor(s), Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak.Detector. Model: Q Electronic Line Leak Detector, Model: <br /> ®Tank Overfill/High-Level Sensor. Model:Flapper/V-R Ext Alarm ❑ Tank Overfill/High-Level Sensor, Model: <br /> ❑ Other(specify equipment a and model in Section E on Pae 2). j ❑ Other(s eci equipment type and model in Section E on Page 2). <br /> Tank ID: Diesel UST]OOOD Gal Tank ID: <br /> Ik]In-Tank Gauging Probe. Model: Mag I ❑ In-Tank Gauging Probe, Model: <br /> 1K7Annular Space or Vault Sensor. Model: 794380-302(Brine) C.]Annular Space or Vault Sensor. Model: <br /> MxPiping Sump/Trench Sensor(s). Model.:794380-208 ❑ Piping Sump/Trench Sensors). Model: <br /> ❑ Fill Sump Sensor(s), Model: d Fill Sump Sensor(s). Model: <br /> ❑ Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector, Model: <br /> Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector, Model: <br /> ®Tank Overfill/High-Level Sensor. Model:Flapper/V-R Ext Alarm ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other s ec' a ui inert g ° el' <br /> q p ftp and tnodel in Section F on Page 2). C3 Other s eci a ui inert a and model in Section E on Page 2). <br /> Sump ID:AST Trans sump Dispenser ID: <br /> ❑ Sump Containment Sensor(s). Model:_794.380-208 El Dispenser Containment Sensors). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dis enser Containment Floats and Chain(s). ❑ Dispenser Containment Floa s and Chain(s). <br /> Dispenser II7: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: Q Dispenser Containment Sensor(s), Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chains). ❑ Dispenser Containment Floa s and Chain(s). <br /> P <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dis enser Containment Floats and Chains}. ❑ Dispenser Containment Float(s)and Chains, <br /> Alf the facility contains more tanks or dispensers,copy this farm. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers` checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. ;Fpr any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): x Syste Alarm h' ory report <br /> Technician Name(print):Peter Jauregui III Signature: <br /> Certification NO.:_B34641 icense.No.: 708231 <br /> Testing Company Name:_Jauregui&Culver inc. Phone No.: (760) 743-0518 <br /> Site Address: 959 W.mission Ave Escondido CA 92025 Date of Testing/Servicing:_11_/_$_/ Za 12 <br /> Page I of 3 03101 <br /> Monitoring System Certification <br />