Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:M".s ov.or lehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility inspection NOV 2012 <br /> Facility Sprint Communications Address: 3807 Coronado Ave, Stockton Date: <br /> Name: Phone: <br /> Faoiliry Title: Manager (209) 993-8205 <br /> Cantact: Ken Carr <br /> Inspectioni Other: <br /> Routine D4 Monitoring System Certification �i installation 'Complaint-ID#: <br /> Type: <br /> (Authority HSC 25289) Ken Carr Title: Manager <br /> Consent for. XInspection IiSampling i i Photos Granted by: <br /> Piping Overfill XMechanical 11 Audiblelvisual <br /> Monitoring Veeder-Root TLS-300C System: ,XPressurized MSuction XGravity Prevention: <br /> Panel <br /> UST2 ----------- -------------- ------------ ----------- - - - - - - - - - - - - - - - - - - - <br /> -Product f"DSL - - - <br /> Designated1Ce Exp. 5,-3-13 Violations: i M1-Release Detection 24M2-Release Prevention M3-Both <br /> Operator Darren Rieck Date: <br /> ICC Exp. Manufacturer's Veeder Root TLS-3XX 7-21-13 <br /> On Site Service Peter JaUregUl Date: 6-22-13 Training: <br /> Technician: <br /> VIOLATIONS <br /> HSG=California HeaNh and Safet Code;CCR=California Code of Re ulations <br /> # C1 C2 M Code Section Cl=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Fite Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> No written agreement between the perso <br /> 103 HSC 25284(x)( n that the operating permit was issued to and the tank operator to <br /> 3) monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program{Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 X CGR 2632(d)(1)(C) Plot planlsite map not submitted or fails to completely shop where monitoring is performed test notification <br /> Secondary containment:(a)test not performed; e)test re ort not submitted within 30 days;(f) <br /> 14$ CCR 2637 not rovided to the EHD at least 48 hours rior to conduc#in the test <br /> Monitoring equipment certification:{a)not performed annually;(d)test report not submitted within 30 days; <br /> ucting an installation,repair, <br /> 109 CCR 2638 (e}test ratification rat provided to the EHD at least 48 hours prior to cond <br /> re lacement,calibration,or certification {M1) <br /> 110 HSG 25291(f) Annual line leak detector test not performed <br /> 111 HSC 25284.2 Annual spill containment testing not perfnrm d <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present [1VI1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> CCR 2660{k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> 115 ermit conditions <br /> Enhanced leak detection{EII testing not performed on a system located within 1000'of public well,or <br /> 116 HSC 25292"5 failures not repaired and retested <br /> 117 CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to Gose UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6'/:years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> CCR 2712{b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> 201 X (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> e ui ment, round water elevations,or other r <br /> test esults; 6 results of inventoryreadin s and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours {M11 <br /> 2p3 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Title <br /> R ved y: <br /> Inspeam.. <br /> Garrett Backus (209) 468-2986 <br /> UST INSPECTION REPORT <br /> Page 1 <br /> EHD 23-02 Rev 041119112 <br />