2300 - Underground Storage Tank Program
>
PR0231066
>
INSTALL_1994
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:36 AM
Creation date
11/2/2018 6:14:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
1994
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\CORONADO\3807\PR0231066\1994 INSTALL.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br />Whenever the tanks are stored at the site, chock them in place to <br />prevent rolling. (See Figure 1-2). Tie them down if high winds are <br />•expected. <br />After delivery and before pre -installation testing, visually inspect <br />the entire exterior surface of the tank for signs of damage (holes, <br />cracks or deep scrapes). <br />Verify that all of the safe -delivery provisions of the Xerxes "Damage <br />Free Delivery" program have been followed. Sign the driver's <br />release form. <br />FIGURE 1-2 <br />11 LATIC <br />All Xerxes tanks are tested prior to shipment but it is required that <br />all tanks be tested prior to installation in order to verify the absence <br />•of shipping and handling damage. In the unlikely event of a leak, it <br />is most likely to develop at a manway or a fitting. After installation <br />and before backfilling to grade, the test must be repeated to verify <br />that no damage has occurred during installation. Refer to the <br />appropriate section below for the instructions for testing a single <br />wall tank, a double wall tank with a dry interstitial space or a double <br />wall tank with a liquid -filled interstitial space. <br />If damage is detected, DO NOT ATTEMPT REPAIRS. Contact the <br />UST Coordinator at the Xerxes plant nearest you or the Technical <br />Service Department at Xerxes' corporate office. Telephone numbers <br />are found on the last page of this manual. <br />Construct a test manifold as shown in Figure 21. The air supply <br />gauge must have a maximum full-scale reading of 15 PSIG with <br />1/4 or 1/10 Ib. increments. <br />WARNING: The pressure relief device or regulated air source must <br />be rated at a maximum of 6 PSIG (4 PSIG for 12 -foot tanks) to <br />reduce the risk of overpressurizing the tank. <br />The tester is responsible for verifying that all of the test equipment <br />is in good working condition and properly configured. <br />• <br />COMPRESSOR <br />IR SUPPLY VALVE <br />PRESSURE RELIEF AIR SUPPLY GAUGE <br />DEVICE <br />TEST MANIFOLD <br />FIGURE 21 <br />ICE FITTING <br />46 <br />WARNING: When the tank is under pressure, the manways and/or <br />fittings may dislodge or the tank may rupture and result in death, <br />severe personal injury, or property damage. Before beginning the <br />test notify all people on the test site to remain in a safe location. <br />ALWAYS ATTEND THE TANK DURING THE TEST. Avoid extended <br />exposure to the manways, fittings and ends of the tank during <br />the test. <br />WARNING: The maximum test pressure is 5 PSIG (3 PSIG when <br />testing a twelve -foot tank). The pressure gauge must be positioned <br />so that the pressure readings can be clearly read at all times. <br />2a. SINGLE WALL TANK TEST <br />1. Open one service fitting. Check to see that all remaining service <br />fittings are properly doped, plugged and tightened. <br />2. Install the test manifold in the open service fitting. Connect the <br />pressure source to the test manifold. (See Figure 2-2). <br />3. Pressurize the tank to 5 PSIG (3 PSIG when testing a 12 -foot <br />tank). Add or remove air as necessary and allow the pressure <br />to stabilize. <br />4. Close the valve on the test manifold. Disconnect the air <br />supply line. <br />5. Monitor the pressure for one hour. Soap the entire exterior of <br />the tank and watch for active air bubbles which indicate a leak. <br />6. When the test is complete, carefully release the air pressure <br />from the tank by opening the air supply valve. The air supply line <br />should already have been disconnected. Remove the test manifold. <br />FROM CONRESSOR <br />PRESSURE RELIEF DEVICE AIR SUPPLY VALVE <br />AIR SUPPLY GAUGE <br />SERVICE FITTING <br />FIGURE 2.2 <br />