Laserfiche WebLink
TLS -254 Series <br />Fixed -Feature Systems <br />TLS -250 and TLS -2501 Systems include <br />features that improve your ability to control <br />inventories, accurately reconcile shift and <br />daily totals, spot losses from theft, identify <br />leaks, and warn of overfills which could <br />cause severe environmental damage. <br />Many of these features, reports and alarm <br />limits are programmable and can be set to <br />match the operating requirements of your <br />installation. In addition, two internal alarm <br />relays can be connected to external alarm <br />devices or security systems and pro- <br />grammed to trigger when any alarm limit <br />has been reached. <br />The ILS -250 provides a low-cost solution <br />to leak detection in double-wall tanks at <br />installations where automated inventory <br />control is not required. It incorporates <br />numerous operating features to provide <br />reliable, automated leak detection and <br />help prevent severe environmental <br />damage. <br />FIYEEOEH-pppT <br />Inventory control and in -tank leak <br />detection for single-wall tanks <br />Inventory Control <br />Capabilities <br />On -Demand Inventory Report <br />• Gallons of Fuel • Inches of Water <br />• Inches of Fuel • Temperature of <br />• Ullage Fuel <br />Automatic Inventory Increase Report <br />In -Tank Leak Detection <br />Capabilities <br />Automatic and On -Demand Leak Tests <br />• Single or all tanks <br />Automatic Leak Test Validity Checks <br />Final Leak Rates with PASS, FAIL and <br />INVALID Leak Test Result Indicators <br />Alarm Capabilities <br />Overfill Alarm Feature <br />Programmable Alarm Limits and Indicators <br />Identify <br />• Theft • High Water <br />• Leak Losses • Overfills <br />• Low Inventory • External Inputs <br />©VEEDER -ROOT <br />Two Alarm Relays Can Trigger Alarm/ <br />Security Devices <br />Programmable Alarm Configuration Ties <br />Any/All Alarm Indicators to Output Relays <br />External Input Interface Integrates Signals <br />from Other Monitoring Devices <br />System Capabilities <br />Programmable Times for Automatic <br />Reporting <br />One System Monitors Up To Eight Tanks <br />Handles Manifolded Tanks <br />RS -232 Communications Interface <br />On -Site and Remote Self -Diagnostics <br />Optional Integral Printer <br />Emergency Generator <br />Version <br />Continuous leak tests <br />Inventory reports available <br />RS -232 communications interface <br />nS-250i Four. and <br />Eight -Tank Systems <br />Inventory control, in -tank leak <br />detection and interstitial leak sensing <br />for double-wall tanks and piping <br />sumps <br />inventory Control <br />Capabilities <br />On -Demand Inventory Report <br />• Gallons of Fuel • Inches of Water <br />• Inches of Fuel • Temperature of <br />• Ullage Fuel <br />Automatic Inventory Increase Report <br />In -Tank Leak Detection <br />Capabilities <br />(Eight -Tank System only) <br />Automatic and On -Demand Leak Tests <br />• Single or all tanks <br />Automatic Leak Test Validity Checks <br />Final Leak Rates with PASS, FAIL and <br />INVALID Leak Test Result Indicators <br />Interstitial Leak Sensing <br />Capabilities <br />Automatic Continuous Leak Sensing <br />• Tank Annulus - Piping Sump <br />Audible and Visual Leak Detect Indicators <br />Show Sensor Location <br />"Sensor Out" Indicators Identify Failed or <br />Disconnected Sensor <br />Alarm Capabilities <br />Overfill Alarm Fealure <br />Programmable Alarm Limits and Indicators <br />Identify <br />• Theft • External inputs <br />• Low Inventory • Leak Losses <br />• High Water (Eight -Tank <br />• Overfills System only) <br />Two Alarm Relays Can Trigger Alarm/ <br />Security Devices <br />Programmable Alarm Configuration Ties <br />Any/All Alarm Indicators to Output Relays <br />External Input Interface Integrates Signals <br />from Other Monitoring Devices <br />System Capabilities <br />Programmable Times for Automatic <br />Reporting <br />Four -Tank System Monitors <br />• Inventory in Four Tanks <br />• Eight Sensors <br />Eight -Tank System Monitors <br />• Inventory in Eight Tanks <br />• Sixteen Sensors <br />Handles Manifolded Tanks <br />RS -232 Communications interface <br />On -Site and Remote Self -Diagnostics <br />Optional Integral Printer <br />Emergency Generator <br />Version <br />(Eight -Tank System only) <br />Continuous leak tests <br />Inventory reports available <br />RS -232 communications interface <br />r <br />Low-cost, stand-alone interstitial leak <br />sensing for double-wall tanks and <br />piping sumps <br />Interstitial Leak Sensing <br />Capabilities <br />Automatic, continuous leak sensing <br />• Tank annulus <br />• Piping sump <br />Audible and visual leak detect indicators <br />show sensor location <br />"Sensor Out" indicators identify failed or <br />disconnected sensor <br />Alarm Capabilities <br />Alarm output relay can trigger alarm/security <br />devices <br />• 8- and 12 -sensor models <br />System Capabilities <br />Available in 4-, 8-, and 12 -sensor models <br />