My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2012
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2725
>
2300 - Underground Storage Tank Program
>
PR0231073
>
COMPLIANCE INFO 2008-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/19/2024 1:34:02 PM
Creation date
11/2/2018 6:36:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2012
RECORD_ID
PR0231073
PE
2361
FACILITY_ID
FA0002064
FACILITY_NAME
7-ELEVEN INC. STORE #14117
STREET_NUMBER
2725
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
02
SITE_LOCATION
2725 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\C\COUNTRY CLUB\2725\PR0231073\COMPLIANCE INFO 2008-2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
402
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONIT NG SYSTEM CERTIFICTI4N <br /> By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,HeM and Safety Code;Chapter 16, Division 3 Title 23, a rnia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The ownerloperator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#14117,MKT 2368 City: STOCKTON CA Zip:95204 <br /> Site Address: 2725 COUNTRY CLUB BLVD Contact Phone No: 463-1259 <br /> Date of Testing/Service: 0312412010 <br /> Facility Contact Person: MANAGER-GIL <br /> Make/Model of Monitoring System:TLS 350R Work Order Number: 2273297 <br /> B.Inventory of Equipment TestedlCertified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> TanklD: 91 TanklD: 87 <br /> X In-Tank Gauging Probe. Model: MAG X In-Tank Gauging Probe, Model: MAG <br /> X Annular Space or Vault Sensor. Model: 420 X Annular Space or Vault Sensor. Model: 420 <br /> X Piping Sump/Trench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model; Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> X Tank Overfill/High-Level:Sensor. Model: FILAPPERIEXTERNAL ALARM Tank Overfill/High-Level Sensor. Model: FLAPPER/EXTERNAL ALARM <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanklD: TanklD: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/7rench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank OverfilllHigh-Level Sensor. Model:. <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 112 Dispenser ID: <br /> ®Dispenser Containment Sensor(s) Model:208 Dispenser Containment Sensor(s) Model: <br /> Q Shear Valve(s). Shear Valve(s) <br /> ElDispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser lD: Dispenser lD: <br /> Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> FShear Valve(s). Shear Valve(s). <br /> 11 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser lD: Dispenser lD: <br /> ❑ Dispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). Shear Valve(s), <br /> 0 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, l have also attached <br /> a copy of the(Check all that apply): System set-up Alarm history report <br /> r <br /> Technician Name(print): STEVEN WILLEMS Signature: <br /> Certification No.: B36743 License.No.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 0312412010 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03108 <br />
The URL can be used to link to this page
Your browser does not support the video tag.