TNK TST SIPHON BREAK:OFF ANNUAL TEST FAIL OUTPUT RELAY SETUP <br /> ALARM DISABLED - - - - - - - - - - - -- <br /> DELIVERY DELAY 3 MIN <br /> PUMP THRESHOLD 10.00% PERIODIC TEST FAIL R I -PUL <br /> ALARM DISABLED TYPE: <br /> STANDARD <br /> GROSS TEST FAIL NORMALLY CLOSED <br /> ALARM DISABLED <br /> TANK 4: 1 <br /> ANN TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF <br /> IN-TANK ALARMS <br /> TANK TEST NOTIFY: OFF T I :LOW PRODUCT ALARM <br /> T I :GROSS TEST FAIL <br /> TNK TST SIPHON BREAKOFF <br /> T 2:RUL LIGUID SENSOR ALMS <br /> PRODUCT CODE 2 DELIVERY DELAY 3 MIN L l :FUEL ALARM <br /> THERMAL COEFF : .000700 PUMP THRESHOLD 10.00% L 5:FUEL ALARM <br /> TANK DIAMETER 96.00 L I :SENSOR OUT ALARM <br /> TANK PROFILE 20 PTS L 5:SENSOR OUT ALARM <br /> FULL VOL 10026 <br /> 91 .2 INCH VOL 9839 ISD SITE ALARMS <br /> 86.4 INCH VOL 9504 ISD GROSS PRES FAIL <br /> e1 .6 INCH VOL 9084 ISD DEGRD PRES FAIL <br /> 76.8 INCH VOL 8599 ISD VAPOR LEAK FAIL <br /> 72.0 INCH VOL 8066 <br /> 67.2 INCH VOL 7496 ISD HOSE ALARMS <br /> 62.4 INCH VOL 6899 ALL:GROSS; COLLECT FAIL <br /> 57.6 INCH VOL 6282 ALL:DEGRD COLLECT FAIL <br /> 52.8 INCH VOL 5651 ALL:FLOW COLLECT FAIL <br /> 48.0 INCH VOL 5014 LEAK TEST METHOD <br /> 43.2 INCH VOL 4376 - - - - - - - - - - - - R 2:RUL <br /> 38.4 INCH VOL 3746 TEST ON DATE : ALL TANK TYPE: <br /> 33.6 INCH VOL 3128 MAR 22, 2011 STANDARD <br /> 28.8 INCH VOL 2530 START TIME : DISABLED NORMALLY CLOSED <br /> 24.0 INCH VOL 1960 TEST RATE :0.20 GAL./HR <br /> 19.2 INCH VOL 1428 DURATION 2 HOURS TANK 0: 2 <br /> 14.4 INCH VOL 944 <br /> 9.6 INCH VOL 522 TST EARLY STOP:DISABLED <br /> 4.8 INCH VOL 188 IN-TANK ALARMS <br /> METER DATA YES LEAK TEST REPORT FORMAT T 2:LOW PRODUCT ALARM <br /> END FACTOR: HEMISPHER NORMAL T 2:GROSS TEST FAIL <br /> CAL UPDATE: NEVER <br /> LIQUID SENSOR ALMS <br /> L 2:FUEL ALARM <br /> FLOAT SIZE: 4.0 IN. L 5:FUEL ALARM <br /> L 2:SENSOR OUT ALARM <br /> WATER WARNING 1 .0 L 5:SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 1 .5 <br /> WATER ALARM FILTER: LOW ISD SITE ALARMS <br /> ISD GROSS PRES FAIL <br /> MAX OR LABEL VOL: 10026 -Z ISD DEGRD PRES FAIL <br /> OVERFILL LIMIT 90% ISD VAPOR LEAK FAIL <br /> 9023 LIQUID SENSOR SETUP <br /> HIGH PRODUCT 95% - - - - - - - - - - - - ISD HOSE ALARMS <br /> 9524 ALL:GROSS COLLECT FAIL <br /> DELIVERY LIMIT 10% L l :PUL STP ALL:DEGRD COLLECT FAIL <br /> 1002 TRI-STATE (SINGLE FLOAT) ALL:FLOW COLLECT FAIL <br /> CATEGORY : STP SUMP <br /> LOW PRODUCT 555 R 3:OVERFILL <br /> LEAK ALARM LIMIT: 15 TYPE: <br /> SUDDEN LOSS LIMIT: 40 L 2:RUL STP STANDARD <br /> TANK TILT 0.00 TRI-STATE (SINGLE FLOAT) NORMALLY OPEN <br /> PROBE OFFSET 0.00 CATEGORY : STP SUMP <br /> TANK #: NONE <br /> SIPHON MANIFOLDED TANKS L 3:PUL ANN <br /> TO: NONE TRI-STATE (SINGLE FLOAT) IN-TANK ALARMS <br /> LINE MANIFOLDED TANKS CATEGORY : ANNULAR SPACE ALL:OVERFILL ALARM <br /> TO: NONE ALL:HIGH PRODUCT ALARM <br /> ALL:MAX PRODUCT ALARM <br /> LEAK MIN PERIODIC: 25% L 4:RUL ANN <br /> 2506 TRI-STATE (SINGLE FLOAT) <br /> CATEGORY : ANNULAR SPACE <br /> LEAK MIN ANNUAL 50% <br /> 5010 <br /> L 5:DISP 1-2 <br /> PERIODIC: TEST TYPE TRI-STATE (SINGLE FLOAT) <br /> STANDARD CATEGORY : DISPENSER PAN <br /> 4f;, <br />