Laserfiche WebLink
HUNTER ENVIRONMENTAL SERVICES, INC. FINAL TEST RESULTS , <br /> 18350 MT. LANGLEY STREET, SUITE 101 TEST DATE: 3/17/88 <br /> FOUNTAIN VALLEY, CA 92708' <br /> 800-247-9014 800-247-2186 <br /> CUSTOMER: SHELL LOCATION/IDENTIFICATION NO.: 20475240493 <br /> ADDRESS: 1313 E. CHARTER WAY <br /> STOCKTON, CA <br /> TEST RESULTS SUMMARY <br /> LEAK LOKATOR RESULTS_________________-___ <br /> SYSTEM ____TANK SIZE____ WATER LEVEL ALR <br /> NO._PRODUCT--------GALLOMS_DIA/MATLINCHESINCHES____ __ GPH------- ONCLUSION_____ RECOMMENDATIONS_ <br /> 1 SIU 8000 95/ST 0 178 +,018 TIGHT <br /> 2 U/L 8000 95/ST TRACE 163 +,015 TIGHT <br /> 3 REG 8000 95/ST 0 165 +.021 TIGHT <br /> OTHER INFO: SWIVEL ON U/L ISLAND 92 VAPOR RECOVERY LEAKING. REPAIRED BEFORE RUNNING TEST. ALSO VERY LARGE AMOUNTS <br /> OF WATER WERE BAILED BUT OF PUMP PITS TO GET TO PUMPS ON REGULAR AND U/L TANKS. <br /> PRODUCT LINES - HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM ---TYPE-OF-r""UMP--- <br /> POUNDS POUNDS MINUTES PRODUCT PRODUCT CONCLUSION <br /> ---- -- ---- <br /> N0,_ PRODUCT______REMOTE____SUCTION___ APPLIEDHELDHELD _ LOS5 CC!sLOSS DPH _/RESULT_______ <br /> I S/U RED JACKET 50 50 10 PASS <br /> 2 UIL RED JACKET 50 47 10 PASS <br /> 3 REG RED JACKET 50 50 10 PASS <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> DETAIL OF TEST RESULTS <br /> TEST TIME -------------- COMPENSATION <br /> TEMPERATURE ABSOLUTE CHECK <br /> SYSTEM TEST LEVEL CLOCK DURATION COMPENSATION LEAK RATE TEST <br /> NO.--PRODUCT----NO.---(IN.)---STATE--(HR-MIN)--CC/DIV--CCIMIN- DELTA oF_ CC/MIN_____ CC/MIN__ GPHY/N________ <br /> I S/U 1 178 10:15 :30 5.853 +10.643 +,028 +9.481 +1.162 +.018 N <br /> 2 U/L 1 163 1:15 :30 5.769 +14.423 +.040 +13.465 +.958 +.015 N <br /> 3 REG 1 165 12:00 :30 6.091 +11.352 +,030 +10.038 +1.314 +.021 N <br /> *LEVEL - Inches from Tank Bottom to Test Level <br /> ALR - Absolute Leak Pate (Measured Leak Rate - Temperature Compensation) in Gallons Per Hour <br /> CONCLUSION - NFPA 329 criterion of +1- 0,05 SPA is used to certify tightness r <br /> CERTIFICATION CEiIRMP ) <br /> This is to certify that the above tank systems were tested, using the HUNTER ENVIRONMENTAL SERVICES, INC. LEAK <br /> LOKATOR according to all standard operating procedures. Those indicated as tight at full system meet the criterion <br /> established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br /> Tests Conducted and Certified By: Test Van No. 19 <br /> Team Manager: R. RENKO <br /> Tank Testing Specialist: C. DORAZIO, <br />