My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1313
>
2300 - Underground Storage Tank Program
>
PR0231049
>
COMPLIANCE INFO_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:24 AM
Creation date
11/2/2018 7:03:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2019
RECORD_ID
PR0231049
PE
2381
FACILITY_ID
FA0003765
FACILITY_NAME
AIRPORT SHELL*
STREET_NUMBER
1313
Direction
E
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
15137007
CURRENT_STATUS
02
SITE_LOCATION
1313 E CHARTER WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CHARTER\1313\PR0231049\COMPLIANCE INFO 1986 - 2008.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
290
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
leak /o_ kato LP, <br /> �.�.p�/, , HNAL REi- DATE OF TEST <br /> 115 DEWALT AVENUE, N.W. TESTI `- '-' <br /> QUITE 400 CONTRACT NUMBER <br /> ANTON, OH 44702 RESULTS <br /> 8-453.1800 800.523-4370 <br /> USTOMER <br /> OCATION—IOENTIFICATION NUMBER NAME <br /> ADDRESS CITY STATE,. <br /> fO` LEAK LOKATOR US <br /> TEST R ESU LTS SUMMARY ONLY <br /> SYSTEM TANK SIZEWATER LEAK LOKATOR RESULTS' COrvc L.CODE <br /> PRODUCT GALLONS DIA/MATL INCHES ILE es GPH corvcwvory RECOMMENDATIONS TEST TANK sys <br /> Cal 7 <br /> uVV 7 ! <1 ) U <br /> ETHER INFORMATION <br /> PRODUCT LINES— HYDROSTATIC PRESSURE TEST RESULTS <br /> SYSTEM TYPE OF PUMP PRODUCT PRODUCT CONCLUSION/ <br /> # MINUTES LOSS LOSS <br /> 10. PRODUCT REMOTE SUCTION APPLIED© APPLIED CC'S GPH RESULT <br /> �ia�� c n j`) f S�� 7- <br /> ,4 <br /> NOTE: On suction systems, NEVER put more than 15 psi on any pump system. <br /> THEIR CONTRACTORS,OFFICIALS,CUSTOMER REPRESENTATIVES PRESENT <br /> DETAIL OF TEST RESULTS <br /> TEMPERATURE ABSOLUTE CREC <br /> Y EM TEST TEST TIME LEAK RATE cDMPErvsnrlory LEAKRATY TEST <br /> LEVEL cwcK Duannon vo.ry <br /> JO. NO• (INCHES) sTARr MRS.MIrv. CC/DIV CC/MIN L *F CC/MIN CC/MIN GPM <br /> r <br /> j - h <br /> L W <br /> 1-! d <br /> rinnx' rL117 <br /> LEVEL- INCHES FROM TANK BOTTOM TO TEST LEVEL <br /> ALR-ABSOLUTE LEAK RATE (MEASURED LEAK RATE-TEMPERATURE COMPENSATION) IN GALLONS PER HOUR <br /> CONCLUSION- NFPA 329 CRITERION OF ±0.05 GPH IS USED TO CERTIFY TIGHTNESS <br /> E RTI FICATION This is to certify that the above described tank systems were tested,using the HUNTER ENVIRONMENTAL <br /> SERVICES, INC. LEAK LOKATOR according to all standard operating procedures.Those indicated as tight at full <br /> system meet the criterion established by the National Fire Protection Association Pamphlet 329 for Precision Testing. <br /> TESTS CONDUCTED BY CERTIFIED BY <br /> TEST VAN NO. TANK TESTING SPECIALIST, SIGNATURE DATE <br /> t _ <br /> ,. dl <br /> TANK TESTING SPEC IALIST NAME TITLE <br />
The URL can be used to link to this page
Your browser does not support the video tag.