COMPLIANCE INFO 2011 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO 2011 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 11:14:22 AM
Creation date
11/2/2018 7:18:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2016
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\COLONY\1442\PR0518458\COMPLIANCE INFO 2011 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
547
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page 6 of 9 <br />7. UNDER -DISPENSER CONTAINMENT (UDC) TESTING <br />Test Method Developed By: ❑ UDC Manufacturer <br />Industry Standard ❑ ProfessionaI Engineer <br />�] Other (Speeif}) <br />Test Method Used: [] Pressure 0 Vacuum <br />® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used See attached testing procedures. <br />y ca <br />Equipment ent <br />Resolution: <br />UDC ##112 imp C#ja -- <br />UDC # 5 <br />UDC Manufacturer: <br />UDC Material: <br />UDC Depth: <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />Condition of UDC prior to <br />Portion of UDC Testees_ <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?" <br />Turbine shutdown response time <br />Is system programmed for fail- <br />safe shutdown?` <br />Was fait -safe verified to be <br />operational?* <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />Test Start Time: <br />Initial Reading (R[): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF-Ri): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testing? <br />16 UPC #7/8 <br />30" <br />3099 <br />30" 4 <br />.. <br />309191 <br />g" <br />899 <br />899 <br />8" <br />4" <br />499 <br />499 <br />'f <br />4a, <br />Fair <br />Fair <br />Fair <br />Fair <br />Above highest <br />penetration <br />Above highest <br />Above highest <br />Abovi <br />enetration <br />penetration <br />6-t <br />®Yes ❑ No z NA� � ❑Yes ❑ No Z NA I ❑ Yes 0 No Z NA 10 Yes ❑ No ® NA <br />❑ Yes ❑ No ® NA <br />]Yes ❑ No ®NA <br />0 Yes ❑ No ®NA <br />❑ Yes ❑ No Z NA <br />❑Yes ❑No0NA <br />E]Yes[]No®NA <br />Oyes ❑No®NA <br />❑Yes ❑NoZNA <br />30 minutes <br />12:04pm <br />1.6096 <br />12:19pm <br />1.6108 <br />15 min <br />0.00125 <br />0.002 <br />30 minutes <br />12:0- <br />2.4075 <br />12:19pm <br />2.4073 <br />15 min <br />0.00021 <br />0.002 <br />Pass L Fail Pass 0 Fall <br />NYes ❑No NA Yes []No ©NA <br />®Yes EjNo [j NA ®Yes []]No DNA <br />30 minutes <br />1..1985 <br />2:07pm <br />1.1985 <br />15 min <br />0.00005 <br />0.002 <br />® Pass ® Fail <br />ZYes ❑No ❑ NA <br />®Yes ❑No 0 NA <br />30 minutes <br />2:16pm <br />1.6307 <br />2:31pm <br />1.6307 <br />15 min <br />0 <br />0.a0z <br />Pass ❑Fail <br />NYes QNo ❑ NA <br />MYes ONo ® NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />I If the entire depth of the UDC is not tested, specify how much was tested. If the answer to �qny of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />