My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2011 - 2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1442
>
2300 - Underground Storage Tank Program
>
PR0518458
>
COMPLIANCE INFO 2011 - 2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/16/2022 11:14:22 AM
Creation date
11/2/2018 7:18:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011 - 2016
RECORD_ID
PR0518458
PE
2361
FACILITY_ID
FA0013918
FACILITY_NAME
CHEVRON STATION #210997*
STREET_NUMBER
1442
STREET_NAME
COLONY
STREET_TYPE
Dr
City
RIPON
Zip
95336
APN
26102028
CURRENT_STATUS
01
SITE_LOCATION
1442 Colony Dr
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\COLONY\1442\PR0518458\COMPLIANCE INFO 2011 - 2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
547
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br />Software Version Installed: 32704 <br />Complete the following checklist: <br />FEB 2 3 2016 <br />ENVIRONMENTAL <br />HFAITU 11MDARTIll <br />• Yes <br />No* <br />s the audible alarm operational? <br />• Yes <br />No <br />s the visual alarm operational? <br />• Yes <br />No* <br />ere all sensors visually inspected, functionally tested, and confirmed operational? <br />• Yes <br />No* <br />ere all sensors installed at lowest point of secondary containment and positioned so that other equipment will interfere <br />heir ro r operation? not wild <br />• Yes <br />No* <br />f alarms are relayed to a remote monitoring station, is all communications equipment (e. g, modem) operational? <br />N/A <br />• Yes <br />No* <br />or pressurized piping systems, doe'�s ltIhe turbine automatically shut down if the piping secondary containment monitoring <br />em detects a leak, fails to operare, or is electrically disconnected? <br />N/A <br />If yes: which sensors initiate positive shut -down? (Check <br />//that apptyF Sump/Trench Sensors; r Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection?(: Yes; r No <br />• Yes <br />No* <br />or tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no mechanical overfill <br />N/A <br />prevention valve is installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? if <br />at what ercent of tankca aci does the alarm tri 1 let?90% <br />• Yes* <br />No <br />as any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced and list the <br />anufacturer name and model for all re lacement arts in Section E below. <br />Yes* <br />• No <br />as liquid found inside any secondary containment systems designed as dry systems? (Check all that app/y) <br />r <br />Product' Water. If Yes, describe causes in Section E below. <br />• Yes <br />No* <br />as monitoring system set-up reviewed <br />to ensure proper settings? Attach set up reports, if applicable <br />• yes <br />No* <br />s all monitonng equipment operation <br />I per manufacturer's specifications? <br />* In Section E below, <br />describe how <br />and when these definenrla<�.,n.n <br />ti. ,.,.n tie .�..,..._. <br />
The URL can be used to link to this page
Your browser does not support the video tag.