PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB January,2002 0 Page of <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑Other(Specify) <br /> Test Method Used: E]Pressure ❑ Vacuum Hydrostatic <br /> []Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Sump# DSL Sump# Sump# Sump# - -Y <br /> Sump Diameter: <br /> Sump Depth: 5 Ft. <br /> Sump Material: <br /> Height from Tank Top to Top of 4 Ft. <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 4 Ft. <br /> Electrical Penetration: <br /> Condition of sump prior to testing: clean <br /> Portion of Sump Tested' <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes ❑ No ® to ❑Yes ❑ No ❑ NA ❑Yes ❑No ❑ NA ❑Yes ❑ No ❑ NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe ❑ym ❑ No H NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑No ❑ NA <br /> shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑ No ® NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and starting 5 MIN <br /> test: <br /> Test Start Time: 8:54 <br /> Initial Reading(RI): 2.9310 <br /> Test End Time: 9:09 <br /> Final Reading(RF): 2.9305 <br /> Test Duration: 15 Min <br /> Change in Reading(RF-R[): .0005 <br /> Pass/Fail Threshold or Criteria: PASSED <br /> Test Result: N Pass ❑ Fail 0 Pass ❑Fail [l Pass D Fail 0 Pass [] Fail <br /> Was sensor removed for testing? N Yes ❑ No ❑ NA iEl Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> Was sensor properly replaced and <br /> verified functional after testing? M Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA ❑Yes ❑ No ❑ NA <br /> Comments--(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> le-st_9 for n, 1 nas_se . Change in reading .0001 <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to aM of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.