My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2001 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CORONADO
>
3807
>
2300 - Underground Storage Tank Program
>
PR0231066
>
COMPLIANCE INFO 2001 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:52:22 AM
Creation date
11/2/2018 7:33:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2001 - 2009
RECORD_ID
PR0231066
PE
2361
FACILITY_ID
FA0003819
FACILITY_NAME
Sprint United Managemnt Co.
STREET_NUMBER
3807
STREET_NAME
CORONADO
STREET_TYPE
Ave
City
Stockton
Zip
95204
CURRENT_STATUS
01
SITE_LOCATION
3807 Coronado Ave
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\IAError\C\CORONADO\3807\PR0231066\COMPLIANCE INFO 2001 - 2009.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
439
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoing System Certific Bion <br /> For Use by All Jurisdictions within the State of California <br /> Authority Cited:Chapter 6.7.Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of Regulations <br /> s form must be used to document testing and servicing of monitoring equipment. Separate certifications or reports must be <br /> Wed for each monitorin stern controlanel by the technician who perfroms the work. A copy of this form must be <br /> pry,. ed to the tank system Owner/Operator. The owner/operator must submit a copy of this form to the local agency regulating <br /> UST systems within 30 days of test date. <br /> ... General Information <br /> acility Name: Stockton,CA Switch Bldg: SET Job#: T7 036784 <br /> ite Address: 3807 Coronado Ave City I State Stockton CA Zip: 95204 <br /> acility Contact Person: Jay Lemes Contact Phone No.: 209-937-5800 <br /> lake 1 Model of Monitoring System: Date of Testing/Servicing: 9/12/1006 <br /> B. Inventory of Equipment Tested or Certified <br /> Check the appropriate boxEs to indicate equipment inspected or serviced-, <br /> Tank ID T-2 UST Diesel Tank ID T4 AST Diesel <br /> Mag I ® In Tank Gauging Probe Mag 1 <br /> In Tank Gauging Probe ago <br /> CK Annular Space or Vault Sensor U2 ® Annular Space or Vault Sensor <br /> 208 Piping Sump/Trench Sensors) T <br /> ® 08 <br /> Piping Sump I Trench Sensors) NIA <br /> ❑ Fill Sump Sensor(s) WA ❑ Fill Sump Sensor(s) <br /> PLLO WA <br /> Mechanical Line Leak Detector ❑ Mechanical Line Leak Detector <br /> ❑ Electronic Line Leak Detector ❑ Electronic Line Leak Detector <br /> ® Tank Overfill/High-Level Sensor 1.3 <br /> 7 300C ® Tank.Overfill/High-Level Sensor 1i3 3DCG <br /> Other(specify equipment type and model in Comments. ❑ Other(specify equipment type and model in Conunents. <br /> Tank ID Tank PD <br /> ❑ In Tank Gauging Probe ❑ In Tank Gauging Probe <br /> ❑ Annular Space or Vault Sensor ❑ Annular Space or Vault Sensor <br /> Piping Sump/Trench Sensors) i _ ❑ Piping Sump/Trench Sensors) <br /> Fill Sump Sensor(s) ❑ Fill Sump Sensor(s) <br /> ❑ Mechanical Line Leak Detector ❑ Mechanical Lane Leak Detector <br /> ❑ Electronic Line Leak Detector ❑ Electronic Line Leak Detector <br /> ❑ Tank Overfill/High-Level Sensor ❑ Tank Overfill/High-Level Sensor <br /> ❑ Other(specify equipment type and model in Comments. ❑ Other(specify equipment type and model in Comments. <br /> Dispenser ID NIA Dispenser ID MA <br /> ❑ Dispenser Containment Sensor(s). <br /> Dispenser Containment Sensor($). <br /> ❑ Shear Valves(s). ❑ Shear Valves(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID Dispenser ID <br /> ❑ Dispenser Containment Sensor(s). ❑ Dispenser Containment Sensor(s). <br /> ❑ Shear Valves(s). ❑ Shear Valves(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID _ Dispenser ID <br /> ❑ Dispenser Containment Sensor(s). ❑ Dispenser Containment Sensor(s). <br /> ❑ Shear Valves(s)_ ❑ Shear Valves($). <br /> ❑ Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance manufacturers' <br /> guidelines.Attached to this certification is information(e.g.manufacturers'checklists)to verify this information is correct <br /> and a plot plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have <br /> also attached a copy of the report(check all that apply) System set-up ® Alarm history <br /> Technician Name(print): Fabian Gomez Signature: �. <br /> Certification No.-. A24225 W License No.: <br /> Testing Company Name: Shirley Environmental Corporation Phone No.: (909)476-7443 <br />
The URL can be used to link to this page
Your browser does not support the video tag.