Laserfiche WebLink
Shir% Environmental Corp&tion <br /> Designated Underground Storage Tank (UST) Operator <br /> Monthly Visual Inspection Checklist <br /> • <br /> Facility Name: Stockton, CA Switch ate: 4-3-2007 <br /> Facility Address: 3807 Coronado Ave <br /> City: Stockton kip Code: 95204 <br /> Designated UST Operator Conducting the Inspection: Daniel Salas <br /> International Code Council Certification#: 5248114-UC Expiration Date: 7-23-2007 <br /> Signature: Phone: 909-476-7443 <br /> Y=Yes, N=No,NA=Not Applicable <br /> Item MONITORING PANEL I ALARM HISTORY Y N NA <br /> 1 Monitoring system is powered on and in proper operating mode. X <br /> 2 Monitoring system is not currently showing any alarms or warnings. X <br /> 3 Alarm history repori for the previous month is available,and has been reviewed by the X <br /> Designated UST Operator. (Attach a copy of the alarm history report4og to this form if available) <br /> 4 Each alarm for the previous month has been responded to appropriately. X <br /> 5 Sensors located in tank-top containment sumps have not alarmed in the past month. X <br /> 5a - List all tank-top sumps where alarms occurred in the past month: <br /> none <br /> Note: Sumps where an alarm has occurred in the past month must be inspected unless a qualified service technician responded to,and <br /> properly addressed,the cause of the alarm. Attach documentation verifying appropriate service to this report. If sump inspection is required, <br /> record results in item 6, below. <br /> MONITORING PANEL 1 ALARM HISTORY <br /> 6Tank-top containment sumps are free of water,debris,and hazardous substance. Sensors are located properly. <br /> Note: Visual inspection of sumps is only required in sumps where an alarm has occurred in the past month for which there is no service record. <br /> Y N Y N <br /> Sump Location: Sump Location: <br /> Sump Location: Sump Location. <br /> Sump Location: Sump Location: <br /> 7 Spill containment structures are free of water,debris, and hazardous substance. <br /> Y N NA Y N NA <br /> Tank 1 - Contents: X ank 3-Contents: X <br /> Tank 2- Contents: X ank 4-Contents: X <br /> 8 Under-dispenser containment areas are free of water,debris and hazardous substance. Sensors are located properly. <br /> Y I N NA I Y N NA <br /> Dispenser 112 X Dispenser 9/10: X <br /> Dispenser 314: X Dispenser 11/12: X <br /> Dispenser 516: X Dispenser 13114: X <br /> Dispenser 718: X Dispenser 15116: 1 1 J_X <br /> PAPERWORK INSPECTION Y N NA DATE DONE <br /> 9 Monitoring system certification has been completed within past 12 months. X 9-12-06 <br /> 10 Secondary containment tests have been completed within the required timeframe. X 10-28-05 <br /> 11 Spill Containment structure(bucket)testing was completed within the past year. X 9-12-06 <br /> 12 Tank tightness testing was completed within required timeframe. X Continuous <br /> 13 Line tightness testing was completed within required timeframe. X No Record <br /> 14 Other required testing/maintenance was completed within required timeframe, (List testlmaintenance items below.) <br /> Test/Maintenance: X <br /> Test/Maintenance; X <br /> Test/Maintenance: X <br /> FACILITY EMPLOYEE TRAINING Y N NA <br /> 15 All facility employees have received the required on-the-job training within the past year. X <br /> 16 111 facility employees hired within the past 30 days have received the required on-the-job training. X <br /> ate:Any answer o ' should be explained in the comment section on the following page,and will requirefollow-up action. <br /> Shirley Environmental Corporation <br /> 9595 Lucas Ranch Road, Suite#100, Rancho Cucamonga, CA 91730 <br /> 800-533-4030 <br />