My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACAMPO
>
4579
>
2300 - Underground Storage Tank Program
>
PR0231504
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/19/2024 1:33:33 PM
Creation date
11/2/2018 7:52:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231504
PE
2381
FACILITY_ID
FA0003573
FACILITY_NAME
A & M MARKET*
STREET_NUMBER
4579
Direction
E
STREET_NAME
ACAMPO
STREET_TYPE
RD
City
ACAMPO
Zip
95220
APN
01703053
CURRENT_STATUS
02
SITE_LOCATION
4579 E ACAMPO RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\ACAMPO\4579\PR0231504\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/23/2011 8:00:00 AM
QuestysRecordID
98691
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORM , WATER RESOURCES CONTRY BOARD <br /> FORM 'B': UNDMGROUND STORAGE TANK PRdtRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWI G INFORMATION FOR EACH TANK. _ Z <br /> .o.. <br /> MARK ONLY ❑ 1 NEW PERMIT F--] 3 RENEWAL PERMIT 5 CHANGE OF INFORMATION F-17 PERMANENTLY CLOSED TANK IC <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED 0, <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: - tl4T U FARM TANK-YES❑ NO Ca <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY Q0 <br /> 00 <br /> A, OWNERS TANK 10 R. MANUFACTURED BY: W <br /> C. YEAR INSTALLED D. TANK CAPACITY IN GALLONS: �}OQ <br /> II. TANK CONTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM <br /> A. EYMOTOR VEHICLE FUEL 2 PETROLEUM B. C. ❑ 1 UNLEADED 2 LEADED ❑ 3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL 1 PRODUCT ❑4 GASAHOL ❑ 5 JET FUEL ❑6 AVIATION GAS <br /> ❑5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN 2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> HAZARDOUS SUBSTANCE STORED 8 C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,6 D <br /> A. TYPE OF ❑ 1 DOUBLE WALED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑ 1 STEEUIRON ❑2 STAINLESS STEEL ❑3 RBERGLASS ❑4 STEEL CLAD WIFIBERGLASS REINFORCED PLASTIC <br /> B. TANK ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> ❑9 BRONZE ❑ 10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> C. INTERIOR ❑ 1 RU88ER LINED ❑2 ALKYD LINING ❑3 EPDXY LINING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS UNING ❑ 6 UNUNED ❑ 95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL' ❑YES ❑ NO ❑ 99 OTHER <br /> D. CORROSION ❑1 POLYETHLENEWRAP ❑2 TAR OR ASPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION [:] 91 NONE ❑95 UNKNOWN ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL CLAD W/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> P S 1VISUALCHECK P 8 2 INVENTORY RECONCILIATION P S 3VADOSEWELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OFGALLON8 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YES [:] NO <br /> � <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANTS NAME(PRINTED 8 SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> AWAN y5- <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE <br /> v _ <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEECODE RECEIPT# BY: <br /> r <br /> FORMS(6-29-66) THIS FORM MUST BE ACCOMPWIED BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS A CURRENT FORMA HAS BEEN FILED (\-, <br /> DATA PROCESSING COPY J <br />
The URL can be used to link to this page
Your browser does not support the video tag.