Laserfiche WebLink
0 0 <br />Page 3 of 4 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />Underground Storage Tank Program Inspection Report" <br />Facility Name: <br />RANCHO SAN MIGUEL MARKET' <br />Facility Address: <br />1427 S AIRPORT WAY STOCKTON <br />Date: <br />June 16 2016 <br />326 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R ❑ COS <br />327 <br />HSC 25298(b) <br />Failed to comply with temporary closure requirements <br />u V ❑ R u COS <br />328 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />❑ V o R ❑ COS <br />329 <br />CCR 2636(f)(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />o V o R o COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />o V o R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />❑ V ❑ R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R o COS <br />Other Violations <br />2010 <br />See below Unlisted Administration/Documentation violation <br />❑ V o R o COS <br />2030 <br />See below Unlisted Operations/Maintenance violation <br />o V ❑ R ❑ COS <br />2060 <br />See below Unlisted Design/Construction violation <br />= V D R L COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />105 <br />CCR 2632 Monitoring and response plans not current or approved by the EHD. <br />The response plan is not current and/or not approved by the EHD. Section V of the Response Plan was left blank. <br />The response plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into <br />CERS, upload the completed form, and submit for review by the EHD. Ensure a copy is available for inspection at any <br />time. <br />This is a minor violation. <br />306 <br />CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br />The test boot in the 91 STP sump was not pulled back and the Schrader was pointed up. Any potential release from <br />the primary containment into the secondary containment in the 91 piping does not flow into a collection sump. All <br />secondary containment systems shall be sloped so that all releases will flow to a collection sump located at the low <br />point of the underground piping. The technician adjusted the test boot so the Schrader valve points down. <br />This was corrected on site. <br />This is a Class II violation. <br />Page 3 of 4 <br />