My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2008-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 4:15:38 PM
Creation date
11/2/2018 8:03:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2015
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2008-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Jun 11 2014 10:41AM law — <br /> Idsh, Aft. <br /> San Joaquin County i IL 116-W <br /> Environmental Health Department JUN Y 1 2014 <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)466-3420 Fair:(209)468-3438 theta: rw.sjgov,dr /gam <br /> ENVIRr NMENTAL HEALTH <br /> .Underground Storage Tank Program Inspection RepnttEPARTMENT <br /> Facility dame: Facility Address: Dat : <br /> RANCHO SAN MIGUEL MARKET` 1427 S AIRPORT WAY, STOCKTON June 05, 2014 <br /> UST System Obsorvations <br /> 328 NSC 25299(1)(2) Tampered with or disabled leak detection devices or alarms ❑V oR ❑COS <br /> 329 CCR 2831.1 UST system not compatible with the substance stored a V o R c C0S <br /> ail} HSC 25296(b) Failed to comply with temporary closure requirements x ©V o R a C0S <br /> 331 HSC 25298(c) Failed to comply with permanent ciosure requirements n V o R a COS <br /> Nan-Preasurized Piping <br /> 401 CCR 263$(x)(3) Suction piping not property sloped or incorrectly located check valve ❑'V ❑R fl COS <br /> 442 CCR 2643(4) Dally monitoring of sodion pipe{pre-Jan 1984)not performed o v ❑Ft a COS <br /> 443 GCR 2643(d) Triennial 0_1 gph line test for nonventlanat snCtlorl plping nol performed(pr"' Twary 1894) o V ti R o 008 <br /> 444 CCR 2643(e) Biennial 17.1 gph test for gravity piping not performed(pre-January 484) o V ❑R ❑COS <br /> Other Violations <br /> 2410 See below Unlisted Adminlstrationrfaocumentalion violation V aR o Cos <br /> 2030 See below Unlisted 4peratlonslMaintenaneo violation o V o R o COS <br /> 2060 See below Unlisted aeslgrdConstruction violation OV o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,011488 Il,or MINOR-Notioe to Comply) <br /> item# Remarks <br /> 104 UST Operating Permit Application for Facility and Tank Information not submitted or currant. UST Tank Information <br /> forms for the two tanks on site are not current and accurate in CERS. Any change of information inust be updated in <br /> CERS within 30 days of the changes, immediately log into CERS, update the required information, and submit for <br /> review b the EHD. Complete a separate tank form for each tank. This is a Class 11 violation. <br /> 106 Monitoring and response plans not current Or approved by the EHD, The monitoring plans are not current and not <br /> approved by the EHD. The monitoring plant;on CERS do not include accurate information for the monitoring equipment <br /> at this site. The monitoring plan must be uploaded to the California Environmental Reporting System (CERS). <br /> immediately log into CERS, make the necessary changes, and submit for review by the EHD, Maintain an approved <br /> copy on Site. This Is a minor violation, <br /> 204 Current monitoring pian approved by the EHD not found on site. An approved copy of the monitoring plans were not <br /> found on site. A copy of these plans shall be retained on site at all times. Immediately locate and retain a copy on site. <br /> This is a repeat violation,Class iI. <br /> Overall Inspection comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by July 5, 2014. <br /> Consent to perform the inspection, take photos and collect samples was given by Gilbert Silva, fuel manager. <br /> This facility's designated operator is Karen Arnaiz (ICC expiration date: 5131115) . The service te0nician was Kris <br /> Bell (iCC expiration date: 10/2114), who had the following manufacturer's certifications: Veeder-Root(expiration <br /> date: 314116), VMI Tester (expiration date: 11119114). <br /> Please he aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Owner/Operator: Written Agreement (if <br /> applicable), UST Letter from Chief Financial Officer, and Owner Statement of Designated UST Operator <br /> Received y(InIllall. nSpector. one: Date: <br /> STACY RIVERA, Senior REHS (209)468-3440 06/0512014 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.