Laserfiche WebLink
Appendix VI E�g=qEo <br /> MONITORING SYSTEM CERTIFICATION AUS; 0 g cU`IU <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited; Chapter 6,7, Health and Safety Code; Chapter 16, Division 3, Title 23, California G 9UNMLN] HEKTH <br /> Regulations pERMIT/SE'RVIGES <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> ownerloperator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility <br /> viz RANCHO SAN MIGUEL Bldg.No.: <br /> Site <br /> Aririrpow 1409 AIRPORT WAY City: STOCKTON Zip: 95205 <br /> Facility Contact <br /> P Prcn nGILBERT Contact Phone No.: <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 613012010 <br /> 8. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced: <br /> Tank ID: 87 Tank ID: <br /> E In-Tank Gauging Probe. Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> E Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> E Piping Sump/Trench Sensor(s). Madel: 208 ❑ Piping Sump I Trench Sensor(s) Model: <br /> E Fill Sump Senscr(s). Model: 208 ❑ Fill Sump Sensor(s). Model <br /> E Mechanical Line Leak Detector, Model: FX 1V ❑ Mechanical Line Leak Detector. Model. <br /> ❑ Electronic Line Leak Detector. Mode4: ❑ Electronic Line Leak Detector. Model <br /> ❑ Tank Overfill/High-Level Sensor. Model: ❑ Tank Overfill/High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: 91 <br /> ❑ In-Tank Gauging Probe. Madel: E In-Tank Gauging Probe. Model: MAG 1 <br /> Annular Space or Vault Sensor. Model E Annular Space or Vault Sensor. Model: SAME TANK <br /> ❑ Piping Sump I Trench Sensor(s). Model: E Piping Sump I Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: E Fill Sump Sensor(s). Model: 208 <br /> ❑ Mechanical Line Leak Detector. Model: E Mechanical Line Leak Detector. Model: STP MLD E <br /> ❑FElectronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> © Tank Overfill/}sigh-Level Sensor. Model: ❑ Tank Overfill f High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 112 Dispenser ID: 314 <br /> E Dispenser Containment Sensor(s). Model: 208 E Dispenser Containment Sensor(s). Model: 208 <br /> E Shear Valve(s). E Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Floats)and Chain(s). <br /> Dispenser ID: 516 Dispenser ID: <br /> E Dispenser Containment Sensor(s). Model: 208 ® Dispenser Containment Sensor(s). Model: <br /> E' Shear Valve(s). ® Shear Valve(s). <br /> Cl Dispenser Containment Floats)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> E Dispenser Containment <br /> E Dispenser Containment Sensor(s). Model: Sensor(s). Model: <br /> E Shear Valve(s). Shear VMve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). Q Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment Identified In this document was Inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is Information(e,g.manufacturers'checklists)necessary to verify that this Information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check ail that npplp): E System set-up E Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: v <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORD_A-TEST Phone No, 209 744-0113 s <br /> Testing Company Address: 416 2" STREET GALT,OA 95632 _ _ Date of TeslinglServicing: 6130110 <br /> Monitoring System Certification Page 1 of 4 21211{)7 <br /> CTS <br />