My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2008-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
COMPLIANCE INFO 2008-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 4:15:38 PM
Creation date
11/2/2018 8:03:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2015
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\COMPLIANCE INFO 2008-2015.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 Appendix VI 6 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16,Division 3,Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> ry=Tility RANCHO SAN MIGUEL Bldg.No.: <br /> Site <br /> Address_ 1409 AIRPORT WAY City: STOCKTON Zip: 95205 <br /> Facility Contact <br /> Persore GILBERT Contact Phone No.: ( ) <br /> Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 6/30/2010 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspectedlserviced: <br /> Tank ID: 87 Tank ID: <br /> ❑ In-Tank Gauging Probe, Model: MAG 1 ❑ In-Tank Gauging Probe. Model: <br /> 0 Annular Space or Vault Sensor. Model: 420 ❑ Annular Space or Vault Sensor. Model: <br /> ® Piping Sump 1 Trench Sensor(s). Model: 208 ❑ Piping Sump/Trench Sensor(s). Model: <br /> ® Fill Sump Sensor(s). Model: 208 ❑ Fill Sump Sensor(s). Model: <br /> ® Mechanical Line Leak Detector. Model: FX 1V ❑ Mechanical Line Leak Detector. Model: <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill!High-Level Sensor. Model: ❑ Tank Overfill i High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> TdnklD: TanklD: 91 <br /> ❑ In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model MAG 1 <br /> ❑ Annular Space or Vault Sensor, Model BJ Annular Space or Vault Sensor. Model: SAME TANK <br /> ❑ Piping Sump 1 Trench Sensor(s). Model: ® Piping Sump 1 Trench Sensor(s). Model: 208 <br /> ❑ Fill Sump Sensor(s). Model: ® Fill Sump Sensor(s). Model: 208 <br /> ❑ Mechanical Line Leak Detector. Model: ® Mechanical Line Leak Detector. Model: STP MLD E <br /> ❑ Electronic Line Leak Detector. Model: ❑ Electronic Line Leak Detector. Model: <br /> ❑ Tank Overfill l High-Level Sensor. Model: ❑ Tank Overfill 1 High-Level Sensor. Model: <br /> ❑ Other(specify equipment type and model in Section E on Page 2). ❑ Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 112 Dispenser ID: 314 <br /> ® Dispenser Containment Sensogs). Model: 208 ❑ Dispenser Containment Sensor(s). Model: 208 <br /> 0 Shear Valve(s). i❑ Shear Valve(s). <br /> Q Dispenser Containment Float(s)and Chain(s)- ❑ Dispenser Containment Flcat(s)and Chain(s). <br /> Dispenser lD: 516 Dispenser ID: <br /> 10 Dispenser Containment Sensogs). Model 208 ® Dispenser Containment Sensor(s). Model: <br /> 0 Shear Valve(s). ® Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Floats)and Chainlsl, <br /> Dispenser ID: Dispenser lD: <br /> ®Dispenser Containment <br /> ® Dispenser Containment Sensor(s). Model: Sensor(s)- Model: <br /> ® Shear Valve(s). Shear Valve(s). <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑'Dispenser Containment Float(s)and Chain(s). <br /> 'if the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was Inspectedlserviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): ®System set-up ®Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0113 <br /> Testing Company Address: 416 2" 5TREET GALT,CA 95632 Date of Testing/Servicing: 6130110 <br /> Monitoring System Certification Page 1 of 4 2121/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.