My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2004
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
1427
>
2300 - Underground Storage Tank Program
>
PR0521942
>
INSTALL_2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2022 10:27:44 AM
Creation date
11/2/2018 8:14:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2004
RECORD_ID
PR0521942
PE
2371
FACILITY_ID
FA0014921
FACILITY_NAME
RANCHO SAN MIGUEL MARKET*
STREET_NUMBER
1427
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
16902016
CURRENT_STATUS
01
SITE_LOCATION
1427 S AIRPORT WAY
P_LOCATION
02
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\1427\PR0521942\INSTALL 2004.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
287
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
&WARIABLE SPEED OPTION IVS21 ap SPECIFICATIONS <br /> CINSTANT FLOW POWER SUPPLY OPTIONS: <br /> Provides constant flow for up to 8 nozzles at a predetermined 60 Hz Applications:Available in 1/3,3/4,1'/2 and 1'/2 hp <br /> flow rate set at installation. high pressure models in 208-230 volt,single phase. <br /> 50 Hz Applications:Available in 3/4,I'/2 and 1'/2 hp high <br /> pressure models in 220-240 volt,single phase,and <br /> 380-415 volt 3 phase. <br /> G 50/60 Hz Applications:2 hp Variable Speed Option for <br /> use with Variable Frequency Controller only.Input <br /> 200-250 volt,50 or 60 Hz,single or 3 phase.Controller <br /> provides 3 phase power to 2 hp variable speed pump <br /> motor. <br /> PUMP MOTOR: <br /> Centrifugal type,directly interchangeable with most <br /> competitive makes, <br /> Maximum liquid viscosity:70 SSU at 60°F(15.50 Q. <br /> Constant flow means faster fueling times during those Thermally protected:Automatic thermal overload turns <br /> daily peak business periods. motor off at approximately 205'F(95'C)and resets <br /> on at approximately 115°F(45'C). <br /> MEETS EPA "SPITIACK" CONTROL LIQUID COMPATIBILITY: <br /> Standard units compatible with fuel mixtures containing <br /> From January 1 1996, up to 15%ethanol or methanol with gasoline and 20% <br /> the EPA requires a MTBE,20%ETBE,or 17%TAME with gasoline,and <br /> maximum flow rate diesel fuels. <br /> per nozzle of 10 GPM. Alcohol/Gasoline models(designated with AG in model <br /> The STP-VS2 meets this number)are compatible in fuel mixtures containing <br /> requirement with a one any combination of ethanol or methanol and gasoline <br /> time investment. and 20%MTBE,20%ETBE,or 17%TAME with <br /> To comply,the maximum gasoline,and diesel fuels. <br /> flow rate for one nozzle is CNECN YAK <br /> adjusted to a maximum of •2 R/<"(70mm)diameter constructed of aluminum and <br /> 10 GPM.The STP-VS2 will steel with fluorocarbon seal.Alcohol gas compatible. <br /> provide a constant flow PRESSURI BELIEF TAETE: <br /> rate for up to 8 nozzles Standard valve is set to relieve static line pressure at 35- <br /> operating simultaneously. 50 PSI(2.38 to 3.4 bar),reseals above 30 PSI(2.0 bar), <br /> Other settings available, <br /> AIA ELIMINATOR: <br /> Returns air to tank with one way check valve to prevent <br /> EPA mandated "Spitback" control is met by the STP'VS2 back flow. <br /> with a simple adjustment during installation, Invest in SIAL ELASTOMERS: <br /> "Spitback"control one time with the STP VS2. All wetted seals on standard units use Vitor?. <br /> Alcohol/Gasoline(AG)models use Viton GFLT® <br /> YAAIAIiE SPEED fluorocarbon seals. <br /> sTPRON: <br /> The Variable Frequency Controller has continuous runningSyphon Primer is venturi type,capable of 26"Hg(66cm) <br /> vacuum. <br /> diagnostics and displays system conditions on the controller: Syphon Check Valve is machined aluminum,field <br /> Dry Run Protection repairable. <br /> Low Incoming Voltage Detection = YANIABLE FNEQNENCY CONTROLLER: <br /> Pump Motor Failure Detection •Alternating lead pump and master/slave capability. <br /> Open Circuit Detection Provides alternating start of the lead pump and <br /> Short Circuit Detection `auto start"of additional pumps in manifolded <br /> Thermal Overload In Controller pump applications. <br /> Controller Capacitors Failings Enclosure size is 5'/R"wide by 10"high by 8'/4"deep <br /> Remote Diagnostic Polling Capability (130mm x 254mm x 210mm). <br /> IPPNOTALS AND/OR LISTINGS: <br /> UL,CSA,BASEEFA,TUV,SAA,BKI,INMETRO,THS, <br /> KHK,FTZU,ROSTEST,others pending. <br /> treduces <br /> te,easily understood display of system conditions QUALITY CEBTIFlCATIDN: <br /> servicetime. FE Petro is an ISO 9001 Certified Manufacturer. <br />