My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
3437
>
2300 - Underground Storage Tank Program
>
PR0504101
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 3:50:36 PM
Creation date
11/2/2018 8:26:15 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0504101
PE
2381
FACILITY_ID
FA0006078
FACILITY_NAME
BP CHEMICALS INC*
STREET_NUMBER
3437
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
17702033
CURRENT_STATUS
02
SITE_LOCATION
3437 S AIRPORT WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\3437\PR0504101\BILLING.PDF
QuestysFileName
BILLING
QuestysRecordDate
11/22/2011 8:00:00 AM
QuestysRecordID
95888
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STATE OF CALIFORNIA WATER RESOURCES CONTROL BOARD <br /> FORM 'S': UNDERGROUND STORAGE TANK PROGRAM <br /> TANK TANK PERMIT APPLICATION INFORMATION ' <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING INFORMATION FOR EACH TANK. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED TANK <br /> ONE ITEM ❑2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANKREMOVED (Dq <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: BP Chemicals Inc. FARM TANK-YES❑ NO ❑R Z <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN—SO SPECIFY •p <br /> A. OWNERS TANK ID# UnknoWnB. MANUFACTURED BY: Unknown <br /> C.YEAR INSTALLED 1972 D. TANK CAPACITY IN GALLONS: SOO <br /> QD <br /> 11. TANK CONTENTS IF(A-1),13 MARKED,COMPLETE ITEM C.IF(0..1),IS NOT MARKED,COMPLETE ITEM D. r <br /> A ❑ 1 MOTOR VEHICLE FUEL ❑2 PETROLEUM e. C. ❑ 1 UNLEADED ❑2 LEADED ❑3 DIESEL <br /> ❑3 CHEMICAL PRODUCT ❑ 4 OIL ❑ 1PRODUCT ❑4 GASAHOL ❑5 JET FUEL 0 6 AVIATION GAS <br /> ❑5 HAZARDOUS 0 80 EMPTY E]95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑ 99 OTHER(DESCRIBE IN ITEM 0,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF Not Applicable HAZARDOUS SUBSTANCE STORED 8 C.A.B.# pp GA.&#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A.B,C.A D <br /> A TYPE OF ❑ I DOUBLE WALLED ❑3 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM ❑2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑99 OTHER <br /> ❑X 1 STEELPRON ❑2 STAINLESS STEEL ❑3.FIBERGLASS ❑4 STEELCIAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANKF-1 5 CONCRETE ❑6 POLYVINYLCHLORIDE F-17 ALUMINUM ❑8100%METHANOL COMPATIBLE FRP <br /> MATERIAL <br /> [:]9 BRONZE ❑10 GALVANIZED STEEL ❑95 UNKNOWN ❑99 OTHER <br /> G INTERIOR F-11 RUBBER UNED ❑ KYD 2 ALUNING F-13 EPDXY UNING ❑4 PHENOLIC LINING <br /> LINING ❑5 GLASS LINING ❑X 6 UNLINED ❑95 UNKNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%MEDIANOL? ❑YES ❑NO ❑99 OTHER <br /> D. CORROSION ❑ 1 POLYETHLENE WRAP L.1GI 2 TARORASPHALT ❑3 VINYL WRAP ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION 5 CATHODIC PROTECTION ❑ 91 NONE ❑95 UNKNOWN ❑99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A FABOVEGROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A SYSTEM TYPE A U 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A(U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> A � 1 STEEL/IRON A U 2 STAINLESSSTEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASSPIPE A U 91 NONE <br /> C.MATERIAL A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEELCLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZEDSTEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 8 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P 8 3 VADOSE WELLS P 8 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> P S 6 PRECISION TESTING P S 7 PRESSURE TESTING P SAZNONE P 8 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE I Not Applicable <br /> 1.ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED OUANTITY OFGILLLONB 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? E]YES ❑ NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED 8 SIGGNNLIFE) DATE <br /> B. Swearingen VJ 2-5-90 <br /> LOCAL AGENCY USE ONLY IY <br /> CO�UNTYY## JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> CURRENT LOCAL AGENCY FACILITY IDN APPROVED BY NAME PHONE#WITH AREA CODE <br /> 503 z1 :3171'-1d <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT 9XPIhATION DATE <br /> CMECK0 PERMIT AMOUNT SURCHARGEAMT. FEE CODE -cCEIPT# BY: <br /> -`-� FORM 8(6-29-88) THIS FORM MUST BE ACCOMPANIEU BY A FACILITY/SITE APPLICATION, FORM 'A',UNLESS AZTRRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />