My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
AIRPORT
>
4800
>
2300 - Underground Storage Tank Program
>
PR0231509
>
COMPLIANCE INFO_2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/7/2019 9:21:46 AM
Creation date
11/2/2018 8:30:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - 2018
RECORD_ID
PR0231509
PE
2361
FACILITY_ID
FA0003809
FACILITY_NAME
A G SPANOS AVIATION DEPT*
STREET_NUMBER
4800
Direction
S
STREET_NAME
AIRPORT
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
17726034
CURRENT_STATUS
01
SITE_LOCATION
4800 S AIRPORT WAY
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS\A\AIRPORT\4800\PR0231509\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
9/14/2017 6:32:41 PM
QuestysRecordID
3636789
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.si4ov.org/ehd <br /> Underground Storage Tank program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> A G SPANOS AVIATION DEPT' (209)982-1550 February 23, 2018 <br /> Facility Address: CERS ID: <br /> 4800 S AIRPORT WAY, STOCKTON, CA 95206 10181439 <br /> Inspection Contact: Title: Rhone: <br /> Thomas Tilley Aviation Support Supervis (209)993-2481 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION-Operating Permit 2361 -UST FACILITY <br /> Consent For: Consent Given By: <br /> Z Inspection ® Photos 0 Samples Thomas Tilley, Aviation Support Supervisor <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> David Winkler 01/29/2020 Thomas Tilley 12119/2018 <br /> Service Technician Manufacturees Training: <br /> VMI, 11109119;VR, 02!08120; TT,03131/20 <br /> CCR-California Cade of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulatlons <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> Fife Review <br /> 101 HSC 25284 Failure to obtain a valid permit to operate from the EHD including but not limited to unpaid fees o V o R ❑COS <br /> 102 HSC 25284(a)(3)(A)/(H) No written agreement between tank owner and tank operator to monitor the tank system o V c R ❑COS <br /> 103 HSC 25292.2,25299.30 Current financial responsibility documents not submitted o V o R o COS <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current m V o R o COS <br /> 105 CCR 2632(4)(1), Failed to have an approved UST monitoring plan ❑V c R o COS <br /> 2634(d) <br /> 106 CCR 2632(d)(2), Failed to have an approved UST response plan o V ❑R ❑COS <br /> 2634(e) <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed a V o R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V ❑R c COS <br /> 109 CCR 2637 Failed to test secondary containment in V a R ®COS <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days c V o R u COS <br /> Ill CCR 2638(a) Failed to test monitoring and leak detection equipment annually ❑V in R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually o V to R n COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V ❑R c COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ❑V to R o COS <br /> 115 CCR 2715(e) Failed to submit to EHD notification of designated operator identification or change will 30 days ❑V ❑R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification ❑V ❑R ❑COS <br /> 117 CCR 2663(h) Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V ❑R ❑COS <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests ❑V n R u COS <br /> 119 HSC 25299(a)(8), Documents were falsified or misrepresented ❑V o R o COS <br /> 25299(b)(7) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification a V o R ❑CCS <br /> 121 CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report ❑V o R o COS <br /> 122 CCR 26310) Failure to submit and maintain UST system component statement of compatibility for substance stored ❑V e R ❑COS <br /> On Site Records <br /> 201 CCR 2712(b) Failure to maintain monitoring,maintenance,and follow up action records ❑V o R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years o V o R ❑COS <br /> FA0003809 PRC231509 SC001 0212312018 <br /> EHD 2M1 Rev.0912,2116 Page 1 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.