Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sipov.ora/ehd/unitiji.htmi <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility address: <br /> CONTINUED <br /> 4800 Airport Way, Stockton Inspection Date: <br /> February 23, 2011 <br /> # Code Section VIOLATIONS <br /> HSC=CA Health 0 Safet Code;CCR=CA Code of Re ulations;V=Violation; li eat Violation V V <br /> Designated operator monthly inspection: (c)(1)alarms not documented; (c)(2-4)spill containers, <br /> 23c CCR 2715(c), (e) UDCs, and sumps(if necessary)not inspected, (c)(5)required test dates not checked or noted;(c)(6) <br /> employee training not verified, (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training: (1)not performed; (2)not current for at least one employee <br /> on site; 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR 2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement, calibration, or certification; (f)performed, and failed to affix a tag/sticker on each <br /> monitorin <br /> --- i ment cpm orient that was certified, repaired. or re laced <br /> 25 HSC 25291 Annual line leak detector test not erformed <br /> 26 HSC 25284.2 Annual s ill containment testing not Performed IM1I <br /> 27 CCR 2636 (4 Annual line ti htness test not erformed ifpositive shutdown or fail safe not resent <br /> 28 CCR 21 Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit Izl <br /> conditions <br /> 29 CCR 2643 e Biennial ti htness test of gravity iinot Performed re-Jarl 1, 1984 <br /> 30 CCR 2641'- Triennial line test for conventional suctionD,iDing not performed re-Janna 1, 1984 IMit <br /> 31 HSC 25292.5 ELD testing not performed on a system located within 1000' of public well, or failures not repaired and <br /> retested <br /> 32 CCR 2661 Permit to re air UST s stem not obtained <br /> 33 HSC 25286 a O erational -pit not amended when UST storage and/or monitoring system chap ed <br /> 34 HSC 25298 b Permit fo tem oraril dose UST s stem not obtained <br /> 35 HSC 25298 c Permit to close UST s stem not obtained <br /> 36 HSC 25299 (2 Tam erin with or disablin leak detection devices or alarms <br /> 37 HSC 25298 a Illegally abandoned UST system <br /> 38 HSC 25281,5 b 2 Unburied fuel iiat marinas oInspected at least dally or to not kept sl <br /> 39 CCR 2631.1 a UST system is not compatible with the substance stored <br /> Eme enc enerator systems <br /> 40 CCR 2636 6 Emer ency generator monitorin s)itstem not checked dailt or to not kept if no leak detector (M1I <br /> 41 HSC 25281.5 b 3 Unburied fueli in not visuall ins ected at least month! or fo not ke t <br /> AB'1702(2003-2004) HSC 25290.2(installed between 07101/03 and 06/30104) {Mi) <br /> VPH S stems HSC 25290.7 installed on or after 07101104 <br /> Compatibility and permeability requirements: (a) UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored; (b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b and d for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) <br /> HSC 25290.2 c 1 Primary containment not liquid or vapor tight <br /> 44 HSC 25290 1(c)(2) <br /> HSC 25290.2(c)(2) Secondary containment not liquid or vapor tight <br /> 45 HSC 25290.1(c)(3) <br /> HSC 25290.2 c 3 Secondary containment not constructed to prevent water intrusion <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment, or IM11 <br /> HSC 25290.2 d the ent of liquid or va or from the rima containment into the seconda containment <br /> 47 HSC 25290.1(e) Interstitial liquid measurement method, constant vacuum, or constant pressure in the interstitial Ili <br /> space of the UST system not maintained <br /> 48 <br /> HSC 25290.10) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection; (2) <br /> HSC 25290.2(i) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation{s)not listed above. <br /> i inspector: <br /> E <br /> ttic <br /> Phone_ <br /> Septic system <br /> Receiv Serves?20 peoplelday <br /> 11 �. Receives other than sanitary waste <br /> (209) 488-3430 Title: psr OtherDYells/French Drains methods: <br /> Xy EH©23-02-01}2 REV 08I13/10 Page 2 <br /> UST INSPECTION REPORT <br />